Specifications Table for ARXS-G

ARXS20G3V1B ARXS20G4V1B ARXS25G3V1B ARXS25G4V1B ARXS35G3V1B ARXS35G4V1B ARXS42G2V1B ARXS42G3V1B ARXS50G2V1B ARXS50G3V1B
Sound pressure level Heating High dBA 47 47 47 47 48 48 48 48
  Cooling High dBA 46 46 46 46 48 48 48 48
Standard Accessories Installation manual 1 1 1 1 1 1 1 1 1 1
  Drain plug 1 1
Refrigerant Charge TCO2Eq 1.7 1.7 2.1 2.1 2.5 2.5 2.7 2.7
  GWP   2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5
  Charge kg 0.8 0.8 1.0 1.0 1.2 1.2 1.3 1.3
  Type   R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A
Piping connections Level difference IU - OU Max. m 15 15 15 15 15 15 15 15
  Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)
Dimensions Unit Width mm 765 765 765 765 765 765 765 765
    Depth mm 285 285 285 285 285 285 285 285
    Height mm 550 550 550 550 550 550 550 550
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Weight Unit kg 32 32 34 34 34 34 39 39
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240
Notes (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting (1) - SL: The silent fan level of the air flow rate setting
  (2) - Contains fluorinated greenhouse gases (2) - Contains fluorinated greenhouse gases (2) - Contains fluorinated greenhouse gases (2) - Contains fluorinated greenhouse gases (2) - Contains fluorinated greenhouse gases (2) - Contains fluorinated greenhouse gases (2) - Contains fluorinated greenhouse gases (2) - Contains fluorinated greenhouse gases
Sound power level Cooling dBA             63
Dimensions Unit Height mm                 735 735
    Width mm                 825 825
    Depth mm                 300 300
Weight Unit kg                 48 48
Compressor Type                   Hermetically sealed swing compressor Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB                 -10 -10
      Max. °CDB                 46 46
  Heating Ambient Min. °CWB                 -15 -15
      Max. °CWB                 20 18
Sound pressure level Cooling High dBA                 48 48
  Heating High dBA                 48 48
Refrigerant Type                   R-410A R-410A
  Charge kg                 1.7 1.7
  Charge tCO2Eq                 3.5 3.5
  GWP                   2087.5 2087.5
Piping connections Piping length OU - IU Max. m                 30 30
  Additional refrigerant charge kg/m                 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)
  Level difference IU - OU Max. m                 20 20
Power supply Phase                   1~ 1~
  Frequency Hz                 50 50
  Voltage V                 220-240 220-240