Specifications Table for ATXS-G / ARXS-G

ATXS20G2V1B / ARXS20G4V1B ATXS20G2V1B / ARXS20G3V1B ATXS25G2V1B / ARXS25G4V1B ATXS25G2V1B / ARXS25G3V1B ATXS35G2V1B / ARXS35G4V1B ATXS35G2V1B / ARXS35G3V1B ATXS50G2V1B / ARXS50G3V1B ATXS50G2V1B / ARXS50G2V1B
Cooling capacity Min. kW 1.3   1.3   1.4   1.7
  Max. kW 2.8   3.2   4.0   5.3
  Nom. kW 2.0 (2)   2.5 (2)   3.5 (2)   5.0 (2)
Space cooling SEER   5.87   6.54   6.43   5.30
  Annual energy consumption kWh/a 119   134   190   330
  Capacity Pdesign kW 2.00   2.50   3.50   5.00
  Energy efficiency class   A+   A++   A++   A
Space heating (Average climate) Capacity Pdesign kW 2.70   2.80   3.60   4.60
  SCOP/A   4.61   4.55   4.32   3.98
  Energy efficiency class   A++   A+   A+   A
  Annual energy consumption kWh/a 819   860   1,167   1,617
Piping connections Liquid OD mm 6.35   6.35   6.35   6.35
  Gas OD mm 9.5   9.5   9.5   12.7
  Drain OD mm 18.0   18.0   18.0   18.0
Nominal efficiency EER   4.26   4.55   4.02   3.29
  Annual energy consumption kWh 235   275   435   760
  COP   4.29   4.53   4.17   3.69
  Energy labeling Directive Cooling   A   A   A   A
    Heating   A   A   A   A
Heating capacity Nom. kW 2.7 (3)   3.4 (3)   4.0 (3)   5.8 (3)
  Min. kW 1.3   1.3   1.4   1.7
  Max. kW 4.3   4.7   5.2   6.5
Notes (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient)
  (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
  (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
Cooling capacity Min. kW   1.3   1.3   1.4   1.7
  Nom. kW   2.0 (3)   2.5 (3)   3.5 (3)   5.0 (3)
  Max. kW   2.8   3.2   4.0   5.3
Heating capacity Min. kW   1.3   1.3   1.4   1.7
  Nom. kW   2.7 (4)   3.4 (4)   4.0 (4)   5.8 (4)
  Max. kW   4.3   4.7   5.2   6.5
Nominal efficiency EER     4.26   4.55   4.02   3.29
  COP     4.29   4.53   4.17   3.69
  Annual energy consumption kWh   235   275   435   760
  Energy labeling Directive Cooling     A   A   A   A
    Heating     A   A   A   A
Piping connections Drain OD mm   18.0   18.0   18.0   18.0
  Gas OD mm   9.5   9.5   9.5   12.7
  Liquid OD mm   6.35   6.35   6.35   6.35
Space cooling Energy efficiency class     A+   A++   A++   A
  Capacity Pdesign kW   2.00   2.50   3.50   5.00
  SEER     5.87   6.54   6.43   5.30
  Annual energy consumption kWh/a   119   134   190   330
Space heating (Average climate) Energy efficiency class     A++   A+   A+   A
  Capacity Pdesign kW   2.70   2.80   3.60   4.60
  SCOP/A     4.61   4.55   4.32   3.98
  Annual energy consumption kWh/a   819   860   1166   1616
Notes   (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load