EHBH04CA3V |
EHBH08CA3V |
EHBH08CA9W |
EHBH16CA3V |
EHBH16CA9W |
Sound pressure level
|
Nom.
|
dBA
|
26
|
26
|
26
|
33
|
33
|
Water side Heat exchanger
|
Water flow rate
|
Heating
|
Max.
|
l/min
|
25
|
34
|
34
|
51
|
51
|
Operation range
|
Heating
|
Water side
|
Max.
|
°C
|
55 (4)
|
55 (4)
|
55 (4)
|
55 (4)
|
55 (4)
|
|
|
|
Min.
|
°C
|
15 (4)
|
15 (4)
|
15 (4)
|
15 (4)
|
15 (4)
|
Sound power level
|
Nom.
|
dBA
|
40 (12)
|
40 (12)
|
40 (12)
|
47 (12)
|
47 (12)
|
Dimensions
|
Unit
|
Width
|
mm
|
480
|
480
|
480
|
480
|
480
|
|
|
Depth
|
mm
|
344
|
344
|
344
|
344
|
344
|
|
|
Height
|
mm
|
890
|
890
|
890
|
890
|
890
|
Casing
|
Material
|
|
Precoated sheet metal
|
Precoated sheet metal
|
Precoated sheet metal
|
Precoated sheet metal
|
Precoated sheet metal
|
|
Colour
|
|
White
|
White
|
White
|
White
|
White
|
Weight
|
Unit
|
kg
|
44
|
46
|
48
|
47
|
48
|
PED
|
Category
|
|
Art3§3
|
Category I
|
Category I
|
Art3§3
|
Art3§3
|
Wiring connections
|
For connection with user interface
|
Remark
|
|
0.75 mm² till 1.25 mm² (max length 500m)
|
0.75 mm² till 1.25 mm² (max length 500m)
|
0.75 mm² till 1.25 mm² (max length 500m)
|
0.75 mm² till 1.25 mm² (max length 500m)
|
0.75 mm² till 1.25 mm² (max length 500m)
|
|
|
Quantity
|
|
2
|
2
|
2
|
2
|
2
|
Notes
|
(1) - With option kit *KHBDP installed: Height = XXX mm
|
(1) - With option kit *KHBDP installed: Height = XXX mm
|
(1) - With option kit *KHBDP installed: Height = XXX mm
|
(1) - With option kit *KHBDP installed: Height = XXX mm
|
(1) - With option kit *KHBDP installed: Height = XXX mm
|
|
(2) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
|
(2) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
|
(2) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
|
(2) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
|
(2) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
|
|
(3) - The sound pressure level mentioned is maximum possible value inside operation range of unit
|
(3) - The sound pressure level mentioned is maximum possible value inside operation range of unit
|
(3) - The sound pressure level mentioned is maximum possible value inside operation range of unit
|
(3) - The sound pressure level mentioned is maximum possible value inside operation range of unit
|
(3) - The sound pressure level mentioned is maximum possible value inside operation range of unit
|
|
(4) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(4) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(4) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(4) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
(4) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
|
|
(5) - Including piping + PHE + back-up heater; excluding expansion vessel
|
(5) - Including piping + PHE + back-up heater; excluding expansion vessel
|
(5) - Including piping + PHE + back-up heater; excluding expansion vessel
|
(5) - Including piping + PHE + back-up heater; excluding expansion vessel
|
(5) - Including piping + PHE + back-up heater; excluding expansion vessel
|
|
(6) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE
|
(6) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE
|
(6) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE
|
(6) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE
|
(6) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE
|
|
(7) - See separate drawing for operation range
|
(7) - See separate drawing for operation range
|
(7) - See separate drawing for operation range
|
(7) - See separate drawing for operation range
|
(7) - See separate drawing for operation range
|
|
(8) - > 50°C BSH only, no heatpump operation
|
(8) - > 50°C BSH only, no heatpump operation
|
(8) - > 50°C BSH only, no heatpump operation
|
(8) - > 50°C BSH only, no heatpump operation
|
(8) - > 50°C BSH only, no heatpump operation
|
|
(9) - BUH 3V/9W can only operate at flow > 12/15 l/min
|
(9) - BUH 3V/9W can only operate at flow > 12/15 l/min
|
(9) - BUH 3V/9W can only operate at flow > 12/15 l/min
|
(9) - BUH 3V/9W can only operate at flow > 12/15 l/min
|
(9) - BUH 3V/9W can only operate at flow > 12/15 l/min
|
|
(10) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
|
(10) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
|
(10) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
|
(10) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
|
(10) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
|
|
(11) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
(11) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
(11) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
(11) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
(11) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
|
(12) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(12) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(12) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(12) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|
(12) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
|