| EHBH04CB3VU / ERLQ004CAV3 | EHBH08CB3VU / ERLQ006CAV3 | EHBH08CB3VU / ERLQ008CAV3 | ||||
|---|---|---|---|---|---|---|
| COP | 5.04 (1), 3.58 (2) | 4.74 (1), 3.56 (2) | 5.04 (1), 3.58 (2) | |||
| Heating capacity | Nom. | kW | 4.40 (1), 4.03 (2) | 6.00 (1), 5.67 (2) | 4.40 (1), 4.03 (2) | |
| Min. | kW | 1.80 (1) | 1.80 (1) | 1.80 (1) | ||
| Max. | kW | 5.12 (1), 4.90 (2) | 8.35 (1), 7.95 (2) | 5.12 (1), 4.90 (2) | ||
| Power input | Heating | Nom. | kW | 0.870 (1), 1.13 (2) | 1.27 (1), 1.59 (2) | 0.870 (1), 1.13 (2) |
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | ||||
| (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | ||||
| (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | ||||
| (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | ||||
| (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | ||||