Specifications Table for EHBH-CBV

EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV
Casing Colour   White White White White
  Material   Precoated sheet metal Precoated sheet metal Precoated sheet metal Precoated sheet metal
Dimensions Unit Height mm 890 890 890 890
    Width mm 480 480 480 480
    Depth mm 344 344 344 344
Weight Unit kg 39.0 41.0 41.0 42.0
PED Category   Art3§3, See note 1 Category I, See note 1 Art3§3, See note 1 Art3§3, See note 1
Sound power level Nom. dBA 40.0 40.0 41.0 44.0
Sound pressure level Nom. dBA 26.0 26.0 27.0 30.0
Operation range Heating Water side Min. °C 10 10 10 10
      Max. °C 55.0 55.0 55.0 55.0
Power supply Name   See note 12 See note 12 See note 12 See note 12
Wiring connections For connection with user interface Quantity   2 2 2 2
    Remark   0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m)
Notes (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel
  (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit.
  (5) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C (5) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C (5) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C (5) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C
  (6) - > 50°C BSH only, no heatpump (6) - > 50°C BSH only, no heatpump (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
      (7) - > 50°C BSH only, no heatpump (7) - > 50°C BSH only, no heatpump