| EHBX11CB3V / ERHQ011BAW1 | EHBX11CB9W / ERHQ011BAW1 | EHBX16CB3V / ERHQ014BAW1 | EHBX16CB9W / ERHQ014BAW1 | EHBX16CB3V / ERHQ016BAW1 | EHBX16CB9W / ERHQ016BAW1 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| COP | 4.30 (1), 3.39 (2) | 4.30 (1), 3.39 (2) | 4.24 (1), 3.22 (2) | 4.24 (1), 3.22 (2) | 4.20 (1), 3.22 (2) | 4.20 (1), 3.22 (2) | ||||
| Cooling capacity | Nom. | kW | 15.1 (1), 11.7 (2) | 15.1 (1), 11.7 (2) | 16.8 (1), 13.1 (2) | 16.8 (1), 13.1 (2) | ||||
| EER | 3.32 (1), 2.72 (2) | 3.32 (1), 2.72 (2) | 2.96 (1), 2.47 (2) | 2.96 (1), 2.47 (2) | 2.72 (1), 2.29 (2) | 2.72 (1), 2.29 (2) | ||||
| Heating capacity | Nom. | kW | 11.3 (1), 11.0 (2) | 11.3 (1), 11.0 (2) | 16.1 (1), 15.1 (2) | 16.1 (1), 15.1 (2) | ||||
| Power input | Heating | Nom. | kW | 2.63 (1), 3.24 (2) | 2.63 (1), 3.24 (2) | 3.82 (1), 4.69 (2) | 3.82 (1), 4.69 (2) | |||
| Cooling | Nom. | kW | 4.53 (1), 4.31 (2) | 4.53 (1), 4.31 (2) | 6.16 (1), 5.73 (2) | 6.16 (1), 5.73 (2) | ||||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||
| (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | |||||
| (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | |||||
| (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | |||||
| (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | |||||
| Heating capacity | Nom. | kW | 14.5 (1), 13.6 (2) | 14.5 (1), 13.6 (2) | ||||||
| Cooling capacity | Nom. | kW | 16.1 (1), 12.6 (2) | 16.1 (1), 12.6 (2) | ||||||
| Power input | Heating | Nom. | kW | 3.42 (1), 4.21 (2) | 3.42 (1), 4.21 (2) | |||||
| Cooling | Nom. | kW | 5.43 (1), 5.08 (2) | 5.43 (1), 5.08 (2) | ||||||
| Space heating | Average climate water outlet 55°C | General | SCOP | 2.80 | 2.80 | |||||
| Seasonal space heating eff. class | A+ | A+ | ||||||||
| Average climate water outlet 35°C | General | SCOP | 3.34 | 3.34 | ||||||
| Seasonal space heating eff. class | A+ | A+ | ||||||||
| Energy Efficiency Range | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | ||||||||