Specifications Table for EHBX-CB

EHBX04CB3V EHBX08CB3V EHBX08CB9W EHBX11CB3V EHBX11CB9W EHBX16CB3V EHBX16CB9W
Sound pressure level Nom. dBA 26.0 (5) 26.0 (5) 26.0 (5)
Operation range Cooling Water side Max. °C 22.0 22.0 22.0
      Min. °C 5.00 (9) 5.00 (9) 5.00 (9)
  Heating Water side Max. °C 55.0 55.0 55.0
      Min. °C 15 (6) 15 (6) 15 (6)
Sound power level Nom. dBA 40.0 (4) 40.0 (4) 40.0 (4)
Dimensions Unit Width mm 480 480 480
    Depth mm 344 344 344
    Height mm 890 890 890
Casing Material   Precoated sheet metal Precoated sheet metal Precoated sheet metal
  Colour   White White White
Weight Unit kg 42.0 44.0 45.0
PED Category   Art3§3, See note 1 Category I, See note 1 Category I, See note 1
Wiring connections For connection with user interface Remark   0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m)
    Quantity   2 2 2
Power supply Name   See note 11 See note 11 See note 11
Electric heater Power supply Frequency Hz 50 50 50
    Voltage V 230 230
    Name   3V3 3V3 9W
    Phase   1~ 1~ Refer to installation manual or drawing 4D093592
Notes (1) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (1) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (1) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel (2) - Including piping + PHE + back-up heater; excluding expansion vessel
  (3) - Including piping + PHE + back-up heater; excluding expansion vessel (3) - Including piping + PHE + back-up heater; excluding expansion vessel (3) - Including piping + PHE + back-up heater; excluding expansion vessel (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (3) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  (4) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (4) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (4) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (4) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit.
  (5) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (5) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (5) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.The sound pressure level mentioned is maximum possible value inside operation range of unit. (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
  (6) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (6) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (6) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (6) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
  (7) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C (7) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C (7) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C (7) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (7) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (7) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (7) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered.
  (8) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (8) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (8) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
  (9) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (9) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered. (9) - If condensation is expected, the installation of a EKHBDP* drain pan kit must be considered.
  (10) - > 50°C BSH only, no heatpump operation (10) - > 50°C BSH only, no heatpump operation (10) - > 50°C BSH only, no heatpump operation
  (11) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (11) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (11) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply.
  (12) - The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (12) - The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. (12) - The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply.
  (13) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase (13) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase (13) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase
  (14) - Select diameter and type according to national and local regulations (14) - Select diameter and type according to national and local regulations (14) - Select diameter and type according to national and local regulations
Casing Colour         White White White White
  Material         Precoated sheet metal Precoated sheet metal Precoated sheet metal Precoated sheet metal
Dimensions Unit Height mm       890 890 890 890
    Width mm       480 480 480 480
    Depth mm       344 344 344 344
Weight Unit kg       43.0 45.0 44.0 46.0
PED Category         Art3§3, See note 1 Art3§3, See note 1 Art3§3, See note 1 Art3§3, See note 1
Sound power level Nom. dBA       41.0 (4) 41.0 (4) 44.0 (4) 44.0 (4)
Sound pressure level Nom. dBA       27.0 (5) 27.0 (5) 30.0 (5) 30.0 (5)
Operation range Heating Water side Min. °C       15 (6) 15 (6) 15 (6) 15 (6)
      Max. °C       55.0 (8) 55.0 (8) 55.0 (8) 55.0 (8)
  Cooling Water side Min. °C       5.00 (9) 5.00 (9) 5.00 (9) 5.00 (9)
      Max. °C       22.0 22.0 22.0 22.0
Power supply Name         See note 11 See note 11 See note 11 See note 11
Electric heater Power supply Name         3V3 9W 3V3 9W
    Phase         1~ Refer to installation manual or drawing 4D093592 1~ Refer to installation manual or drawing 4D093592
    Frequency Hz       50 50 50 50
    Voltage V       230   230
Wiring connections For connection with user interface Quantity         2 2 2 2
    Remark         0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m)