| EHVH04S18CA3V | EHVH08S18CA3V | EHVH08S26CA9W | EHVH16S18CA3V | EHVH16S26CA9W | |||||
|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Nom. | dBA | 28 | 28 | 33 | 33 | |||
| Water side Heat exchanger | Water flow rate | Heating | Max. | l/min | 34 | 34 | 50 | 50 | |
| Operation range | Heating | Water side | Max. | °C | 55 (5) | 55 (5) | 55 (5) | 55 (5) | |
| Min. | °C | 15 (5) | 15 (5) | 15 (5) | 15 (5) | ||||
| Sound power level | Nom. | dBA | 42 (2) | 42 (2) | 47 (2) | 47 (2) | |||
| Dimensions | Unit | Width | mm | 600 | 600 | 600 | 600 | ||
| Depth | mm | 728 | 728 | 728 | 728 | ||||
| Height | mm | 1,732 | 1,732 | 1,732 | 1,732 | ||||
| Casing | Material | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | ||||
| Colour | White | White | White | White | |||||
| Weight | Unit | kg | 116 | 126 | 120 | 129 | |||
| PED | Category | Category I | Category I | Art3§3 | Art3§3 | ||||
| Wiring connections | For connection with user interface | Remark | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | |||
| Quantity | 2 | 2 | 2 | 2 | |||||
| Notes | (1) - Heatloss according to EN12897 | (1) - Heatloss according to EN12897 | (1) - Heatloss according to EN12897 | (1) - Heatloss according to EN12897 | (1) - Heatloss according to EN12897 | ||||
| (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | |||||
| (3) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (3) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (3) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (3) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (3) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | |||||
| (4) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (4) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (4) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (4) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (4) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | |||||
| (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | |||||
| (6) - Including piping + PHE + back-up heater; excluding expansion vessel | (6) - Including piping + PHE + back-up heater; excluding expansion vessel | (6) - Including piping + PHE + back-up heater; excluding expansion vessel | (6) - Including piping + PHE + back-up heater; excluding expansion vessel | (6) - Including piping + PHE + back-up heater; excluding expansion vessel | |||||
| (7) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE | (7) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE | (7) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE | (7) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE | (7) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE | |||||
| (8) - See separate drawing for operation range | (8) - See separate drawing for operation range | (8) - See separate drawing for operation range | (8) - See separate drawing for operation range | (8) - See separate drawing for operation range | |||||
| (9) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation | (9) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation | (9) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation | (9) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation | (9) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation | |||||
| (10) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation | (10) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation | (10) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation | (10) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation | (10) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation | |||||
| (11) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *3V models 12 l/min | (11) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *3V models 12 l/min | (11) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *3V models 12 l/min | (11) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *3V models 12 l/min | (11) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *3V models 12 l/min | |||||
| (12) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *9W models 15 l/min | (12) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *9W models 15 l/min | (12) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *9W models 15 l/min | (12) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *9W models 15 l/min | (12) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safety a higher minimum flow is required. For *9W models 15 l/min | |||||
| (13) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | (13) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | (13) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | (13) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | (13) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | |||||
| (14) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (14) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (14) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (14) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (14) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||||
| (15) - For more details on current & voltage range, refer to the installation manual. | (15) - For more details on current & voltage range, refer to the installation manual. | (15) - For more details on current & voltage range, refer to the installation manual. | (15) - For more details on current & voltage range, refer to the installation manual. | (15) - For more details on current & voltage range, refer to the installation manual. | |||||
| Casing | Colour | White | |||||||
| Material | Precoated sheet metal | ||||||||
| Dimensions | Unit | Height | mm | 1,732 | |||||
| Width | mm | 600 | |||||||
| Depth | mm | 728 | |||||||
| Weight | Unit | kg | 115 | ||||||
| PED | Category | Art3§3 | |||||||
| Water side Heat exchanger | Water flow rate | Heating | Max. | l/min | 25 | ||||
| Sound power level | Nom. | dBA | 42 (2) | ||||||
| Sound pressure level | Nom. | dBA | 28 | ||||||
| Operation range | Heating | Water side | Min. | °C | 15 (5) | ||||
| Max. | °C | 55 (5) | |||||||
| Wiring connections | For connection with user interface | Quantity | 2 | ||||||
| Remark | 0.75 mm² till 1.25 mm² (max length 500m) | ||||||||