Specifications Table for EHVH-C3VF

EHVH04S18CA3VF EHVH08S18CA3VF
Sound pressure level Nom. dBA 28 28
Water side Heat exchanger Water flow rate Heating Max. l/min 25 34
Operation range Heating Water side Max. °C 55 (5) 55 (5)
      Min. °C 15 (5) 15 (5)
Sound power level Nom. dBA 42 (2) 42 (2)
Dimensions Unit Width mm 600 600
    Depth mm 728 728
    Height mm 1,732 1,732
Casing Material   Precoated sheet metal Precoated sheet metal
  Colour   White White
Weight Unit kg 120 121
PED Category   Art3§3 Category I
Wiring connections For connection with user interface Remark   0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m)
    Quantity   2 2
Electric heater Current back-up heater Running current A 13 13
  Power supply Frequency Hz 50 50
    Voltage V 230 230
    Phase   1~ 1~
Notes (1) - Heatloss according to EN12897 (1) - Heatloss according to EN12897
  (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (2) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  (3) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. (3) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
  (4) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow (4) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow
  (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (5) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
  (6) - Including piping + PHE + back-up heater; excluding expansion vessel (6) - Including piping + PHE + back-up heater; excluding expansion vessel
  (7) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE (7) - Water circuit piping connections diameter is connection after ball valves, Connection at unit is G1-1/4 FEMALE
  (8) - See separate drawing for operation range (8) - See separate drawing for operation range
  (9) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation (9) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation
  (10) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safely a higher minimum flow is required:12 l/min (10) - Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safely a higher minimum flow is required:12 l/min
  (11) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. (11) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit.
  (12) - For more details on current & voltage range, refer to the installation manual. (12) - For more details on current & voltage range, refer to the installation manual.
  (13) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (13) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC