| EHVH04S18CB3VF | EHVH08S18CB3VF | ||||
|---|---|---|---|---|---|
| Sound pressure level | Nom. | dBA | 28.0 (7) | 28.0 (7) | |
| Sound power level | Nom. | dBA | 42.0 (6) | 42.0 (6) | |
| Dimensions | Unit | Width | mm | 600 | 600 |
| Depth | mm | 728 | 728 | ||
| Height | mm | 1,732 | 1,732 | ||
| Casing | Material | Precoated sheet metal | Precoated sheet metal | ||
| Colour | White | White | |||
| Weight | Unit | kg | 121 | 123 | |
| PED | Category | Art3§3, See note 1 | Category I, See note 1 | ||
| Wiring connections | For connection with user interface | Remark | 0.75 mm² till 1.25 mm² (max length 500m) | 0.75 mm² till 1.25 mm² (max length 500m) | |
| Quantity | 2 | 2 | |||
| Power supply | Name | See note 14 | See note 14 | ||
| Electric heater | Power supply | Frequency | Hz | 50 | 50 |
| Voltage | V | 230 | 230 | ||
| Name | 3V3 | 3V3 | |||
| Phase | 1~ | 1~ | |||
| Notes | (1) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (1) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||
| (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | ||||
| (3) - Based on a dT of 45 K | (3) - Based on a dT of 45 K | ||||
| (4) - Including piping + PHE + back-up heater; excluding expansion vessel | (4) - Including piping + PHE + back-up heater; excluding expansion vessel | ||||
| (5) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | (5) - Excluding the water in the unit. This minimum water volume is sufficient for most applications. During critical processes extra water may be required. | ||||
| (6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | ||||
| (7) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (7) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | ||||
| (8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | ||||
| (9) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C | (9) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C | ||||
| (10) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | (10) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models | ||||
| (11) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation | (11) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation | ||||
| (12) - Unit performances refer to ideal running conditions that are reproducible in laboratory test environment in accordance to recognized industry standards (i.e. EN14511) | (12) - Unit performances refer to ideal running conditions that are reproducible in laboratory test environment in accordance to recognized industry standards (i.e. EN14511) | ||||
| (13) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation | (13) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation | ||||
| (14) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. | (14) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. | ||||
| (15) - Select diameter and type according to national and local regulations | (15) - Select diameter and type according to national and local regulations | ||||