| EHVH16SU26CB6W / ERLQ016CAW1 | EHVH11SU26CB6W / ERLQ011CAW1 | EHVH16SU26CB6W / ERLQ014CAW1 | ||||
|---|---|---|---|---|---|---|
| Domestic hot water heating | General | Declared load profile | XL | XL | ||
| Average climate | Water heating energy efficiency class | A | A | |||
| COP | 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) | 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) | ||||
| Heating capacity | Nom. | kW | 11.2 (1), 11.0 (2) | 14.5 (1), 13.6 (2) | ||
| Max. | kW | 8.60 (3), 8.60 (4) | 10.6 (3), 10.8 (4) | |||
| Power input | Heating | Max. | kW | 3.13 (3), 4.10 (4) | 4.00 (3), 5.19 (4) | |
| Nom. | kW | 2.43 (1), 3.10 (2) | 3.37 (1), 4.10 (2) | |||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||
| (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | |||||
| (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | |||||
| (5) - Tamb 35°C - LWE 7°C (DT=5°C) | (5) - Tamb 35°C - LWE 7°C (DT=5°C) | |||||
| (6) - Tamb 35°C - LWE 18°C (DT=5°C) | (6) - Tamb 35°C - LWE 18°C (DT=5°C) | |||||
| (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | |||||
| (8) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (8) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | |||||
| Energy Efficiency Range | Space Heating A+++ ~ D, Water Heating A+ ~ F | |||||