Specifications Table for EHVZ-CB3V

EHVZ04S18CB3V EHVZ08S18CB3V EHVZ16S18CB3V
Casing Colour   White White White
  Material   Precoated sheet metal Precoated sheet metal Precoated sheet metal
Dimensions Unit Height mm 1,732 1,732 1,732
    Width mm 600 600 600
    Depth mm 728 728 728
Weight Unit kg 121 122 121
PED Category   Art3§3, See note 1 Category I, See note 1 Art3§3, See note 1
Sound power level Nom. dBA 42 42 44 (6)
Sound pressure level Nom. dBA 28 28 30 (7)
Operation range Heating Water side Min. °C 15 15 15 (8)
      Max. °C 55 55 55 (9)
Power supply Name   See note 12 See note 12 See note 12
Electric heater Power supply Name   3V3 3V3 3V3
    Phase   1~ 1~ 1~
    Frequency Hz 50 50 50
    Voltage V 230 230 230
Wiring connections For connection with user interface Quantity   2 2 2
    Remark   0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m)
Notes (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (1) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (2) - Heatloss according to EN12897 (2) - Heatloss according to EN12897 (2) - Heatloss according to EN12897
  (3) - Including piping + PHE + back-up heater; excluding expansion vessel (3) - Including piping + PHE + back-up heater; excluding expansion vessel (3) - Including piping + PHE + back-up heater; excluding expansion vessel
  (4) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (4) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (4) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  (5) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. (5) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. (5) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
  (6) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (6) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (6) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
  (7) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation (7) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation (7) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
      (8) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation
      (9) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation