| EKHVH008BB6V3 | EKHVH008BB6WN | EKHVH008BB9WN | EKHVH016BB6V3 | EKHVH016BB6WN | EKHVH016BB9WN | ||||
|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Medium speed | 0 ESP | dBA | 28 (9) | 28 (9) | 28 (9) | 28 (15) | 28 (15) | 28 (15) |
| Sound power level | Medium speed | 0 ESP | dBA | 42 | 42 | 42 | 46 | 46 | 46 |
| Dimensions | Unit | Width | mm | 600 | 600 | 600 | 600 | 600 | 600 |
| Depth | mm | 695 | 695 | 695 | 695 | 695 | 695 | ||
| Height | mm | 705 | 705 | 705 | 705 | 705 | 705 | ||
| Casing | Material | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | Precoated sheet metal | ||
| Colour | Metallic grey | Metallic grey | Metallic grey | Metallic grey | Metallic grey | Metallic grey | |||
| Weight | Unit | kg | 65 | 65 | 65 | 67 | 67 | 67 | |
| Wiring connections | For connection with user interface | Remark | Cable section minimum 0.75mm², maximum length 500m | Cable section minimum 0.75mm², maximum length 500m | Cable section minimum 0.75mm², maximum length 500m | Cable section minimum 0.75mm², maximum length 500m | Cable section minimum 0.75mm², maximum length 500m | Cable section minimum 0.75mm², maximum length 500m | |
| Quantity | 2 | 2 | 2 | 2 | 2 | 2 | |||
| Electric heater | Current back-up heater | Running current | A | 26 (18) | 8.7 (19) | 13 (20) | 26 (24) | 8.7 (25) | 13 (26) |
| Power supply | Frequency | Hz | 50 | 50 | 50 | ||||
| Voltage | V | 230 | 400 | 400 | 230 | 400 | 400 | ||
| Phase | 1~ | 3~ | 3~ | 1~ | 3~ | 3~ | |||
| Notes | (1) - In combination with ERHQ006BAV3 | (1) - In combination with ERHQ006BAV3 | (1) - In combination with ERHQ006BAV3 | (1) - In combination with ERHQ011BAV3 | (1) - In combination with ERHQ011BAV3 | (1) - In combination with ERHQ011BAV3 | |||
| (2) - In combination with ERLQ006BAV3 | (2) - In combination with ERLQ006BAV3 | (2) - In combination with ERLQ006BAV3 | (2) - In combination with ERLQ011BAV3 | (2) - In combination with ERLQ011BAV3 | (2) - In combination with ERLQ011BAV3 | ||||
| (3) - In combination with ERHQ007BAV3 | (3) - In combination with ERHQ007BAV3 | (3) - In combination with ERHQ007BAV3 | (3) - In combination with ERHQ011BAW1 | (3) - In combination with ERHQ011BAW1 | (3) - In combination with ERHQ011BAW1 | ||||
| (4) - In combination with ERLQ007BAV3 | (4) - In combination with ERLQ007BAV3 | (4) - In combination with ERLQ007BAV3 | (4) - In combination with ERLQ011BAW1 | (4) - In combination with ERLQ011BAW1 | (4) - In combination with ERLQ011BAW1 | ||||
| (5) - In combination with ERHQ008BAV3 | (5) - In combination with ERHQ008BAV3 | (5) - In combination with ERHQ008BAV3 | (5) - In combination with ERHQ014BAV3 | (5) - In combination with ERHQ014BAV3 | (5) - In combination with ERHQ014BAV3 | ||||
| (6) - In combination with ERLQ008BAV3 | (6) - In combination with ERLQ008BAV3 | (6) - In combination with ERLQ008BAV3 | (6) - In combination with ERLQ014BAV3 | (6) - In combination with ERLQ014BAV3 | (6) - In combination with ERLQ014BAV3 | ||||
| (7) - Tamb 35°C - LWE 7°C (Dt=5°C) at high speed | (7) - Tamb 35°C - LWE 7°C (Dt=5°C) at high speed | (7) - Tamb 35°C - LWE 7°C (Dt=5°C) at high speed | (7) - In combination with ERHQ014BAW1 | (7) - In combination with ERHQ014BAW1 | (7) - In combination with ERHQ014BAW1 | ||||
| (8) - DB/WB 7°C/6°C - LWC 35°C (Dt=5°C) at high speed | (8) - DB/WB 7°C/6°C - LWC 35°C (Dt=5°C) at high speed | (8) - DB/WB 7°C/6°C - LWC 35°C (Dt=5°C) at high speed | (8) - In combination with ERLQ014BAW1 | (8) - In combination with ERLQ014BAW1 | (8) - In combination with ERLQ014BAW1 | ||||
| (9) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (9) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (9) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (9) - In combination with ERHQ016BAV3 | (9) - In combination with ERHQ016BAV3 | (9) - In combination with ERHQ016BAV3 | ||||
| (10) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (10) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (10) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (10) - In combination with ERLQ016BAV3 | (10) - In combination with ERLQ016BAV3 | (10) - In combination with ERLQ016BAV3 | ||||
| (11) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (11) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (11) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (11) - In combination with ERHQ016BAW1 | (11) - In combination with ERHQ016BAW1 | (11) - In combination with ERHQ016BAW1 | ||||
| (12) - Including piping + PHE + back-up heater; excluding expansion vessel | (12) - Including piping + PHE + back-up heater; excluding expansion vessel | (12) - Including piping + PHE + back-up heater; excluding expansion vessel | (12) - In combination with ERLQ016BAW1 | (12) - In combination with ERLQ016BAW1 | (12) - In combination with ERLQ016BAW1 | ||||
| (13) - See separate drawing for operation range | (13) - See separate drawing for operation range | (13) - See separate drawing for operation range | (13) - Tamb 35°C - LWE 7°C (Dt=5°C) at high speed | (13) - Tamb 35°C - LWE 7°C (Dt=5°C) at high speed | (13) - Tamb 35°C - LWE 7°C (Dt=5°C) at high speed | ||||
| (14) - Operation range: only with optional *KHTS* tank. Water temperatures higher than 50°C are with BUH only. More details, see operation range drawnig | (14) - Operation range: only with optional *KHTS* tank. Water temperatures higher than 50°C are with BUH only. More details, see operation range drawnig | (14) - Operation range: only with optional *KHTS* tank. Water temperatures higher than 50°C are with BUH only. More details, see operation range drawnig | (14) - DB/WB 7°C/6°C - LWC 35°C (Dt=5°C) at high speed | (14) - DB/WB 7°C/6°C - LWC 35°C (Dt=5°C) at high speed | (14) - DB/WB 7°C/6°C - LWC 35°C (Dt=5°C) at high speed | ||||
| (15) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. | (15) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. | (15) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. | (15) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (15) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | (15) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | ||||
| (16) - Electric heater has 2 capacity steps | (16) - Electric heater has 2 capacity steps | (16) - Electric heater has 2 capacity steps | (16) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (16) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | (16) - The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow | ||||
| (17) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (17) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (17) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (17) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (17) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | (17) - 15°C-25°C: BUH only, no heat pump operation = during commissioning | ||||
| (18) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (18) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (18) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (18) - Including piping + PHE + back-up heater; excluding expansion vessel | (18) - Including piping + PHE + back-up heater; excluding expansion vessel | (18) - Including piping + PHE + back-up heater; excluding expansion vessel | ||||
| (19) - The installer can reduce the capacity of the heater from 6 to 2kW. The current is then reduced from 8.7 to 5A. Please refer to the installation manual for instructions. | (19) - The installer can reduce the capacity of the heater from 6 to 2kW. The current is then reduced from 8.7 to 5A. Please refer to the installation manual for instructions. | (19) - The installer can reduce the capacity of the heater from 6 to 2kW. The current is then reduced from 8.7 to 5A. Please refer to the installation manual for instructions. | (19) - See operation range drawing for difference between single & three phase units | (19) - See operation range drawing for difference between single & three phase units | (19) - See operation range drawing for difference between single & three phase units | ||||
| (20) - The installer can reduce the capacity of the heater from 9 to 3kW. The current is then reduced from 13 to 7.5A. Please refer to the installation manual for instructions. | (20) - The installer can reduce the capacity of the heater from 9 to 3kW. The current is then reduced from 13 to 7.5A. Please refer to the installation manual for instructions. | (20) - The installer can reduce the capacity of the heater from 9 to 3kW. The current is then reduced from 13 to 7.5A. Please refer to the installation manual for instructions. | (20) - Operation range: only with optional *KHTS* tank. Water temperatures higher than 55°C are with BUH only. More details, see operation range drawnig | (20) - Operation range: only with optional *KHTS* tank. Water temperatures higher than 55°C are with BUH only. More details, see operation range drawnig | (20) - Operation range: only with optional *KHTS* tank. Water temperatures higher than 55°C are with BUH only. More details, see operation range drawnig | ||||
| (21) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (21) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (21) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (21) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. | (21) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. | (21) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. | ||||
| (22) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (22) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (22) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (22) - Optional electric heater has 2 capacity steps except for the 3V3 model which has only 1 capacity step. | (22) - Optional electric heater has 2 capacity steps except for the 3V3 model which has only 1 capacity step. | (22) - Optional electric heater has 2 capacity steps except for the 3V3 model which has only 1 capacity step. | ||||
| (23) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (23) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (23) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | |||||||
| (24) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (24) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | (24) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A. Please refer to the installation manual for instructions. | |||||||
| (25) - The installer can reduce the capacity of the heater from 6 to 2kW. The current is then reduced from 8.7 to 5A. Please refer to the installation manual for instructions. | (25) - The installer can reduce the capacity of the heater from 6 to 2kW. The current is then reduced from 8.7 to 5A. Please refer to the installation manual for instructions. | (25) - The installer can reduce the capacity of the heater from 6 to 2kW. The current is then reduced from 8.7 to 5A. Please refer to the installation manual for instructions. | |||||||
| (26) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 13 to 7.5A. Please refer to the installation manual for instructions. | (26) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 13 to 7.5A. Please refer to the installation manual for instructions. | (26) - The installer can reduce the capacity of the heater from 6 to 3kW. The current is then reduced from 13 to 7.5A. Please refer to the installation manual for instructions. | |||||||
| (27) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (27) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (27) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | |||||||
| (28) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (28) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (28) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | |||||||