Specifications Table for ERHQ-BBV3

ERHQ006BBV3 ERHQ007BBV3 ERHQ008BBV3
Sound pressure level Heating Nom. dBA 48 48 49
  Cooling Nom. dBA 48 48 50
Standard Accessories Installation manual 1 1 1
Refrigerant Charge TCO2Eq 3.5 3.5 3.5
  GWP   2,087.5 2,087.5 2,087.5
  Charge kg 1.7 1.7 1.7
  Type   R-410A R-410A R-410A
Piping connections Liquid OD mm 6.35 6.35 6.35
  Gas OD mm 15.9 15.9 15.9
  Drain OD mm 20 20 20
  Level difference IU - OU Max. m 20 20 20
Sound power level Heating Nom. dBA 61 61 62
  Cooling Nom. dBA 63 63 63
Dimensions Unit Width mm 825 825 825
    Depth mm 300 300 300
    Height mm 735 735 735
Weight Unit kg 56 56 56
Power supply Phase   1~ 1~ 1~
  Name   V3 V3 V3
  Frequency Hz 50 50 50
  Voltage V 230 230 230
Current Recommended fuses A 20 20 20
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - Operation range heating (outdoor unit): range increase by support back-up heater (2) - Operation range heating (outdoor unit): range increase by support back-up heater (2) - Operation range heating (outdoor unit): range increase by support back-up heater
  (3) - Operation range domestic hot water (outdoor unit): range increase by support booster heater (3) - Operation range domestic hot water (outdoor unit): range increase by support booster heater (3) - Operation range domestic hot water (outdoor unit): range increase by support booster heater
  (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
  (5) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (5) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase (5) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
  (6) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax (6) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax (6) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax
  (7) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (7) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (7) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
  (8) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (8) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (8) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
  (9) - Contains fluorinated greenhouse gases (9) - Contains fluorinated greenhouse gases (9) - Contains fluorinated greenhouse gases