| ERHQ011BAW1 | ERHQ014BAW1 | ERHQ016BAW1 | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 51 (5) | 51 (5) | 52 (5) | |
| Cooling | Nom. | dBA | 50 (6) | 52 (6) | 54 (6) | ||
| Sound power level | Heating | Nom. | dBA | 64 (3) | 64 (3) | 66 (3) | |
| Cooling | Nom. | dBA | 64 (4) | 66 (4) | 69 (4) | ||
| Refrigerant | Charge | TCO2Eq | 6.3 | 6.3 | 6.3 | ||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | ||||
| Charge | kg | 3.0 | 3.0 | 3.0 | |||
| Type | R-410A | R-410A | R-410A | ||||
| Dimensions | Unit | Width | mm | 900 | 900 | 900 | |
| Depth | mm | 320 | 320 | 320 | |||
| Height | mm | 1,345 | 1,345 | 1,345 | |||
| Weight | Unit | kg | 108 | 108 | 108 | ||
| Operation range | Cooling | Max. | °CDB | 46.0 | 46.0 | ||
| Min. | °CDB | 10.0 | 10.0 | ||||
| Domestic hot water | Min. | °CDB | -20 (2) | -20 (2) | |||
| Max. | °CDB | 35 (2) | 35 (2) | ||||
| Piping connections | Heat insulation | Both liquid and gas pipes | Both liquid and gas pipes | Both liquid and gas pipes | |||
| Liquid | OD | mm | 9.52 | 9.52 | 9.52 | ||
| Gas | OD | mm | 15.90 | 15.90 | 15.90 | ||
| Drain | OD | mm | 26 | 26 | 26 | ||
| Level difference | IU - OU | Max. | m | 30.0 | 30.0 | 30.0 | |
| Power supply | Phase | 3N~ | 3N~ | 3N~ | |||
| Name | W1 | W1 | W1 | ||||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 400 | 400 | 400 | |||
| Current | Recommended fuses | A | 20 | 20 | 20 | ||
| Notes | (1) - Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range. | (1) - Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range. | (1) - Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range. | ||||
| (2) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. | (2) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. | (2) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. | |||||
| (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (4) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | (4) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | (4) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C) | |||||
| (5) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 | (5) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). | (5) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 | |||||
| (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = | (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = 5°C). | (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = | |||||
| (7) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (7) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (7) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | |||||
| (8) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. | (8) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. | (8) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. | |||||
| (9) - Contains fluorinated greenhouse gases | (9) - Contains fluorinated greenhouse gases | (9) - Contains fluorinated greenhouse gases | |||||