| ERLQ006BBV39 | ERLQ007BBV39 | ERLQ008BBV39 | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 48 | 48 | 49 | |
| Cooling | Nom. | dBA | 48 | 48 | 50 | ||
| Standard Accessories | Installation manual | 1 | 1 | 1 | |||
| Refrigerant | Charge | TCO2Eq | 3.5 | 3.5 | 3.5 | ||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | ||||
| Charge | kg | 1.7 | 1.7 | 1.7 | |||
| Type | R-410A | R-410A | R-410A | ||||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | |
| Gas | OD | mm | 15.9 | 15.9 | 15.9 | ||
| Drain | OD | mm | 20 | 20 | 20 | ||
| Level difference | IU - OU | Max. | m | 20 | 20 | 20 | |
| Sound power level | Heating | Nom. | dBA | 61 | 61 | 62 | |
| Cooling | Nom. | dBA | 63 | 63 | 63 | ||
| Dimensions | Unit | Width | mm | 825 | 825 | 825 | |
| Depth | mm | 300 | 300 | 300 | |||
| Height | mm | 735 | 735 | 735 | |||
| Weight | Unit | kg | 57 | 57 | 57 | ||
| Power supply | Phase | 1~ | 1~ | 1~ | |||
| Name | V3 | V3 | V3 | ||||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 230 | 230 | 230 | |||
| Current | Recommended fuses | A | 20 | 20 | 20 | ||
| Notes | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | ||||
| (2) - Operation range heating (outdoor unit): range increase by support back-up heater | (2) - Operation range heating (outdoor unit): range increase by support back-up heater | (2) - Operation range heating (outdoor unit): range increase by support back-up heater | |||||
| (3) - Operation range domestic hot water (outdoor unit): range increase by support booster heater | (3) - Operation range domestic hot water (outdoor unit): range increase by support booster heater | (3) - Operation range domestic hot water (outdoor unit): range increase by support booster heater | |||||
| (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | |||||
| (5) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase | (5) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase | (5) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase | |||||
| (6) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (6) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | (6) - In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax | |||||
| (7) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (7) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | (7) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A | |||||
| (8) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (8) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (8) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||||
| (9) - Contains fluorinated greenhouse gases | (9) - Contains fluorinated greenhouse gases | (9) - Contains fluorinated greenhouse gases | |||||