Specifications Table for ERLQ-BW1

ERLQ011BAW1 ERLQ014BAW1 ERLQ016BAW1
Sound pressure level Heating Nom. dBA 51 51 52
  Cooling Nom. dBA 50 52 54
Standard Accessories Tie-wraps 2 2 2
  Installation manual 1 1 1
Refrigerant Charge TCO2Eq 6.2 6.2 6.2
  GWP   2,087.5 2,087.5 2,087.5
  Charge kg 2.95 2.95 2.95
  Type   R-410A R-410A R-410A
Piping connections Heat insulation   Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
  Liquid OD mm 9.52 9.52 9.52
  Gas OD mm 15.9 15.9 15.9
  Drain OD mm 26 26 26
  Level difference IU - OU Max. m 30 30 30
Sound power level Heating Nom. dBA 64 64 66
  Cooling Nom. dBA 64 66 69
Dimensions Unit Width mm 900 900 900
    Depth mm 320 320 320
    Height mm 1,345 1,345 1,345
Weight Unit kg 108 108 108
Power supply Phase   3N~ 3N~ 3N~
  Name   W1 W1 W1
  Frequency Hz 50 50 50
  Voltage V 400 400 400
Current Recommended fuses A 20 20 20
Notes (1) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (1) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (1) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
  (2) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. (2) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. (2) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit.
  (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (4) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (4) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (4) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (5) - Contains fluorinated greenhouse gases (5) - Contains fluorinated greenhouse gases (5) - Contains fluorinated greenhouse gases