| ERLQ011BAW1 | ERLQ014BAW1 | ERLQ016BAW1 | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 51 | 51 | 52 | |
| Cooling | Nom. | dBA | 50 | 52 | 54 | ||
| Standard Accessories | Tie-wraps | 2 | 2 | 2 | |||
| Installation manual | 1 | 1 | 1 | ||||
| Refrigerant | Charge | TCO2Eq | 6.2 | 6.2 | 6.2 | ||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | ||||
| Charge | kg | 2.95 | 2.95 | 2.95 | |||
| Type | R-410A | R-410A | R-410A | ||||
| Piping connections | Heat insulation | Both liquid and gas pipes | Both liquid and gas pipes | Both liquid and gas pipes | |||
| Liquid | OD | mm | 9.52 | 9.52 | 9.52 | ||
| Gas | OD | mm | 15.9 | 15.9 | 15.9 | ||
| Drain | OD | mm | 26 | 26 | 26 | ||
| Level difference | IU - OU | Max. | m | 30 | 30 | 30 | |
| Sound power level | Heating | Nom. | dBA | 64 | 64 | 66 | |
| Cooling | Nom. | dBA | 64 | 66 | 69 | ||
| Dimensions | Unit | Width | mm | 900 | 900 | 900 | |
| Depth | mm | 320 | 320 | 320 | |||
| Height | mm | 1,345 | 1,345 | 1,345 | |||
| Weight | Unit | kg | 108 | 108 | 108 | ||
| Power supply | Phase | 3N~ | 3N~ | 3N~ | |||
| Name | W1 | W1 | W1 | ||||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 400 | 400 | 400 | |||
| Current | Recommended fuses | A | 20 | 20 | 20 | ||
| Notes | (1) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (1) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (1) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | ||||
| (2) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. | (2) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. | (2) - Down to 3m with recharging of the outdoor unit. Please refer to the installation manual of the outdoor unit. | |||||
| (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (4) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (4) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (4) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (5) - Contains fluorinated greenhouse gases | (5) - Contains fluorinated greenhouse gases | (5) - Contains fluorinated greenhouse gases | |||||