|
ERLQ011CAW1 |
ERLQ014CAW1 |
ERLQ016CAW1 |
Sound pressure level
|
Heating
|
Nom.
|
dBA
|
|
51 (5)
|
52 (5)
|
|
Cooling
|
Nom.
|
dBA
|
|
52 (5)
|
54 (5)
|
Sound power level
|
Heating
|
Nom.
|
dBA
|
|
64 (3)
|
66 (3)
|
|
Cooling
|
Nom.
|
dBA
|
|
66 (4)
|
69 (4)
|
Refrigerant
|
GWP
|
|
|
2,087.5
|
2,087.5
|
|
Charge
|
kg
|
|
3.4
|
3.4
|
|
Type
|
|
|
R-410A
|
R-410A
|
Dimensions
|
Unit
|
Width
|
mm
|
|
900
|
900
|
|
|
Depth
|
mm
|
|
320
|
320
|
|
|
Height
|
mm
|
|
1,345
|
1,345
|
Weight
|
Unit
|
kg
|
|
114
|
114
|
Operation range
|
Cooling
|
Max.
|
°CDB
|
|
46.0
|
46.0
|
|
|
Min.
|
°CDB
|
|
10.0
|
10.0
|
|
Domestic hot water
|
Min.
|
°CDB
|
|
-20 (2)
|
-20 (2)
|
|
|
Max.
|
°CDB
|
|
35 (2)
|
35 (2)
|
Piping connections
|
Heat insulation
|
|
|
Both liquid and gas pipes
|
Both liquid and gas pipes
|
|
Liquid
|
OD
|
mm
|
|
9.52
|
9.52
|
|
Gas
|
OD
|
mm
|
|
15.90
|
15.90
|
|
Drain
|
OD
|
mm
|
|
26
|
26
|
|
Level difference
|
IU - OU
|
Max.
|
m
|
|
30.0
|
30.0
|
Power supply
|
Phase
|
|
|
3N~
|
3N~
|
|
Name
|
|
|
W1
|
W1
|
|
Frequency
|
Hz
|
|
50
|
50
|
|
Voltage
|
V
|
|
400
|
400
|
Current
|
Recommended fuses
|
A
|
|
20
|
20
|
Notes
|
(1) - Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range.
|
(1) - Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range.
|
(1) - Operation range heating (outdoor unit): range increase by support back-up heater. See separate drawing for operation range.
|
|
(2) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
|
(2) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
|
(2) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
|
|
(3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
|
(4) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C)
|
(4) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C)
|
(4) - Condition: Ta 35°C - LWE 7°C ( DT = 5°C)
|
|
(5) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
|
(5) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
|
(5) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
|
|
|
(6) - Contains fluorinated greenhouse gases
|
(6) - Contains fluorinated greenhouse gases
|
Dimensions
|
Unit
|
Height
|
mm
|
1345
|
|
|
Width
|
mm
|
900
|
|
|
Depth
|
mm
|
320
|
Weight
|
Unit
|
kg
|
114
|
Operation range
|
Cooling
|
Min.
|
°CDB
|
10
|
|
|
Max.
|
°CDB
|
46
|
|
Domestic hot water
|
Min.
|
°CDB
|
-20 (2)
|
|
|
Max.
|
°CDB
|
35 (2)
|
Sound power level
|
Heating
|
Nom.
|
dBA
|
64 (3)
|
|
Cooling
|
Nom.
|
dBA
|
64 (4)
|
Sound pressure level
|
Heating
|
Nom.
|
dBA
|
51 (5)
|
|
Cooling
|
Nom.
|
dBA
|
50 (5)
|
Refrigerant
|
Type
|
|
R-410A
|
|
GWP
|
|
2087.5
|
|
Charge
|
tCO2Eq
|
7.1
|
|
Charge
|
kg
|
3.4
|
Piping connections
|
Liquid
|
OD
|
mm
|
9.52
|
|
Gas
|
OD
|
mm
|
15.9
|
|
Drain
|
OD
|
mm
|
26
|
|
Level difference
|
IU - OU
|
Max.
|
m
|
30.0
|
|
Heat insulation
|
|
Both liquid and gas pipes
|
Power supply
|
Name
|
|
W1
|
|
Phase
|
|
3N~
|
|
Frequency
|
Hz
|
50
|
|
Voltage
|
V
|
400
|
Current
|
Recommended fuses
|
A
|
20
|