| FAA71AUVEB / AZAS71M2V1B | FAA100AUVEB / AZAS100M7V1B | ||||
|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 6.80 (1) | ||
| Space cooling | SEER | 5.77 | |||
| Annual energy consumption | kWh/a | 412 | |||
| Capacity | Pdesign | kW | 6.80 | ||
| Energy efficiency class | A+ | ||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 4.50 | |
| SCOP/A | 3.81 | ||||
| Energy efficiency class | A | ||||
| Annual energy consumption | kWh/a | 1,654 | |||
| Heating capacity | Nom. | kW | 7.50 (2) | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | |||||
| (4) - See separate drawing for electrical data | |||||
| Cooling capacity | Nom. | kW | 9.50 | ||
| Heating capacity | Nom. | kW | 10.8 | ||
| Space cooling | Energy efficiency class | A | |||
| Capacity | Pdesign | kW | 9.50 | ||
| SEER | 5.25 | ||||
| Annual energy consumption | kWh/a | 633 | |||
| Space heating (Average climate) | Energy efficiency class | A | |||
| Capacity | Pdesign | kW | 6.00 | ||
| SCOP/A | 3.81 | ||||
| Annual energy consumption | kWh/a | 2205 | |||