Specifications Table for FBQ-C8

FBQ35C8VEB FBQ50C8VEB FBQ60C8VEB FBQ71C8VEB FBQ100C8VEB FBQ125C8VEB FBQ140C8VEB
Sound pressure level Heating High dBA 37 37 37 37 38 40 41
    Low dBA 29 29 29 29 32 33 34
  Cooling Low dBA 29 29 29 29 32 33 33
    High dBA 37 37 37 37 38 40 40
Cooling capacity Total capacity Nom. kW 3.4 (1) 5.0 (1) 5.7 (1) 7.1 (1) 10.0 (1) 12.5 (1) 13.4 (1)
Piping connections Liquid OD mm 6.35 6.35 6.35 9.52 9.52 9.52 9.52
  Gas OD mm 9.5 12.7 12.7 15.9 15.9 15.9 15.9
  Drain   VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25)
Required ceiling void > mm 350 350 350 350 350 350 350
Power input Cooling Nom. kW 0.140 0.140 0.350 0.350 0.350 0.350 0.350
  Heating Nom. kW 0.140 0.140 0.350 0.350 0.350 0.350 0.350
Sound power level Cooling dBA 63 63 57 57 61 66 66
Dimensions Unit Width mm 700 700 1,000 1,000 1,400 1,400 1,400
    Depth mm 700 700 700 700 700 700 700
    Height mm 300 300 300 300 300 300 300
Casing Colour   Not painted (galvanised) Not painted (galvanised) Not painted (galvanised) Not painted (galvanised) Not painted (galvanised) Not painted (galvanised) Not painted (galvanised)
Weight Unit kg 25 25 34 34 45 45 45
Fan External static pressure High Pa 100 100 100 100 120 120 120
    Nom. Pa 30 30 30 30 40 50 50
Drain-up height mm 625 625 625 625 625 625 625
Decoration panel Weight kg 3.5 3.5 4.5 4.5 6.5 6.5 6.5
  Model   BYBS45DJW1 BYBS45DJW1 BYBS71DJW1 BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1
  Dimensions Height mm 55 55 55 55 55 55 55
    Depth mm 500 500 500 500 500 500 500
    Width mm 800 800 1,100 1,100 1,500 1,500 1,500
  Colour   White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5)
Heating capacity Total capacity Nom. kW 4.0 (2) 5.5 (2) 7.0 (2) 8.0 (2) 11.2 (2) 14.0 (2) 15.5 (2)
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~
  Name   VE VE VE VE VE VE VE
  Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220
Notes (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
  (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
  (4) - The sound pressure values are mentioned for a unit installed with rear suction. (4) - The sound pressure values are mentioned for a unit installed with rear suction. (4) - The sound pressure values are mentioned for a unit installed with rear suction. (4) - The sound pressure values are mentioned for a unit installed with rear suction. (4) - The sound pressure values are mentioned for a unit installed with rear suction. (4) - The sound pressure values are mentioned for a unit installed with rear suction. (4) - The sound pressure values are mentioned for a unit installed with rear suction.
  (5) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (5) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (5) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (5) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (5) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (5) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (5) - PED unit category: Art3§3: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC