Specifications Table for FCQG-E / RZQG-L

FCQG71EVEB / RZQG71LV1B FCQG100EVEB / RZQG100LV1B FCQG125EVEB / RZQG125LV1B FCQG140EVEB / RZQG140LV1B
Cooling capacity Nom. kW 7.1 (3) 10.0 (3) 12.0 (3) 14.0 (3)
Space cooling SEER   4.67 (5) 4.62 (5) 4.43
Nominal efficiency EER   3.84 4.05 3.60 3.21
  Annual energy consumption kWh 925 1,235 1,665 2,180
  COP   4.71 4.71 4.24 4.01
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Heating capacity Nom. kW 8.0 (4) 11.2 (4) 14.0 (4) 16 (4)
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient)
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal)
  (4) - Heating: indoor temp. 20°CDB, 15°CWB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal); (4) - Heating: indoor temp. 20°CDB, 15°CWB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal); (4) - Heating: indoor temp. 20°CDB, 15°CWB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal); (4) - Heating: indoor temp. 20°CDB, 15°CWB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal);
  (5) - SEER: Pr-EN14825 - inquiry version 2010 (5) - SEER: Pr-EN14825 - inquiry version 2010 (5) - SEER: Pr-EN14825 - inquiry version 2010 (5) - All data mentioned is preliminary information
  (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load