FFQ25B8V1B / RXS25J2V1B FFQ35B8V1B / RXS35J2V1B FFQ50B8V1B / RXS50J2V1B (Preliminary)
Cooling capacity Nom. kW 2.5 (3) 3.4 (3)
Nominal efficiency EER   3.42 3.09
  Annual energy consumption kWh 365 550
  COP   3.48 3.33
  Energy labeling Directive Cooling   A B
    Heating   B C
Heating capacity Nom. kW 3.2 (4) 4.0 (4)
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient)
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (5) - All data mentioned is preliminary information (5) - All data mentioned is preliminary information (5) - All data mentioned is preliminary information
  (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (6) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load