| FHQ35BWV1B / RXS35J2V1B | FHQ50BWV1B / RXS50J2V1B | ||||
|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.4 | 1.7 | |
| Max. | kW | 3.7 | 5.6 | ||
| Nom. | kW | 3.4 (3) | 5.0 (3) | ||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 |
| Gas | OD | mm | 9.5 | 12.7 | |
| Drain | OD | mm | VP20 (External dia.26, Internal dia. 20) | VP20 (External dia.26, Internal dia. 20) | |
| Nominal efficiency | EER | 3.24 | 2.73 | ||
| Annual energy consumption | kWh | 525 | 915 | ||
| COP | 3.60 | 2.93 | |||
| Energy labeling Directive | Cooling | A | D | ||
| Heating | B | D | |||
| Heating capacity | Nom. | kW | 4.0 (4) | 6.0 (4) | |
| Min. | kW | 1.2 | 1.7 | ||
| Max. | kW | 5.0 | 7.0 | ||
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | ||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | ||||
| (5) - 220V | (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||
| (6) - 230V | |||||
| (7) - 240V | |||||
| (8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | |||||