Specifications Table for FLXS-B / RXS-J

FLXS25BAVMB / RXS25J2V1B FLXS35BAVMB / RXS35J2V1B FLXS50BAVMB / RXS50J2V1B
Cooling capacity Min. kW 1.2 1.2 0.9
  Max. kW 3.0 3.8 5.3
  Nom. kW 2.5 (3) 3.5 (3) 4.9 (3)
Piping connections Liquid OD mm 6.35 6.35 6.35
  Gas OD mm 9.5 9.5 12.7
  Drain OD mm 18.0 18.0 18.0
Nominal efficiency EER   3.85 3.10 2.85
  Annual energy consumption kWh 325 565 860
  COP   3.47 3.25 3.35
  Energy labeling Directive Cooling   A B C
    Heating   B C C
Heating capacity Nom. kW 3.4 (4) 4.0 (4) 6.1 (4)
  Min. kW 1.2 1.4 0.9
  Max. kW 4.5 5.0 7.5
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient)
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (5) - 220V (5) - 220V (5) - 220V
  (6) - 230V (6) - 230V (6) - 230V
  (7) - 240V (7) - 240V (7) - 240V
  (8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load