| FLXS25BAVMB / RXS25K2V1B | FLXS25BAVMB / RXS25K3V1B | FLXS35BAVMB / RXS35K2V1B | FLXS50BAVMB / RXS50K2V1B | ||||
|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.2 | 1.2 | 1.2 | 0.9 | |
| Max. | kW | 3.0 | 3.0 | 3.8 | 5.3 | ||
| Nom. | kW | 2.5 (3) | 2.5 (2) | 3.5 (2) | 4.9 (2) | ||
| Space cooling | SEER | 4.46 | 4.49 | 5.09 | |||
| Annual energy consumption | kWh/a | 196 | 273 | 337 | |||
| Capacity | Pdesign | kW | 2.50 | 3.50 | 4.90 | ||
| Energy efficiency class | C | C | B | ||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.80 | 2.90 | 4.50 | |
| SCOP/A | 3.63 | 3.42 | 3.68 | ||||
| Energy efficiency class | A | A | A | ||||
| Annual energy consumption | kWh/a | 1,080 | 1,186 | 1,708 | |||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 |
| Gas | OD | mm | 9.5 | 9.5 | 9.5 | 12.7 | |
| Drain | OD | mm | 18 | 18.0 | 18.0 | 18.0 | |
| Nominal efficiency | EER | 3.85 | 3.85 | 3.10 | 2.85 | ||
| Annual energy consumption | kWh | 325 | 325 | 565 | 860 | ||
| COP | 3.47 | 3.47 | 3.25 | 3.35 | |||
| Energy labeling Directive | Cooling | A | A | B | C | ||
| Heating | B | B | C | C | |||
| Heating capacity | Nom. | kW | 3.4 (4) | 3.4 (3) | 4.0 (3) | 6.1 (3) | |
| Min. | kW | 1.2 | 1.2 | 1.4 | 0.9 | ||
| Max. | kW | 4.5 | 4.5 | 5.0 | 7.5 | ||
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | ||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m | (4) - 220V | (4) - 220V | (4) - 220V | ||||
| (5) - 220V | (5) - 230V | (5) - 230V | (5) - 230V | ||||
| (6) - 230V | (6) - 240V | (6) - 240V | (6) - 240V | ||||
| (7) - 240V | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||
| (8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | |||||||