FLXS25BAVMB |
FLXS50BAVMB |
FLXS60BAVMB |
Sound pressure level
|
Heating
|
High
|
dBA
|
37
|
46
|
47
|
|
|
Medium
|
dBA
|
|
|
42
|
|
|
Silent operation
|
dBA
|
29
|
33
|
34
|
|
|
Low
|
dBA
|
31
|
35
|
37
|
|
Cooling
|
Medium
|
dBA
|
|
|
45
|
|
|
Silent operation
|
dBA
|
28
|
36
|
39
|
|
|
Low
|
dBA
|
31
|
39
|
41
|
|
|
High
|
dBA
|
37
|
47
|
48
|
|
|
Nom.
|
dBA
|
34
|
41
|
42
|
|
Cooling
|
Nom.
|
dBA
|
34
|
43
|
45
|
Standard Accessories
|
Installation and operation manual
|
1
|
1
|
|
Infrared remote control
|
1
|
1
|
|
Batteries
|
2
|
2
|
2
|
|
Remote control holder
|
1
|
1
|
1
|
|
Air purification filter
|
1
|
1
|
1
|
|
Heat insulation tube (refrigerant pipe)
|
1
|
2
|
|
Mounting plate
|
1
|
1
|
1
|
|
Side cover
|
2
|
2
|
2
|
|
Binding band
|
4
|
4
|
4
|
|
Photocatalytic deodorizing filter
|
1
|
1
|
1
|
Control systems
|
Infrared remote control
|
|
ARC433B67
|
ARC433B67
|
ARC433B67
|
Piping connections
|
Liquid
|
OD
|
mm
|
6.35
|
6.35
|
6.35
|
|
Gas
|
OD
|
mm
|
9.52
|
12.7
|
12.7
|
|
Drain
|
|
18
|
18
|
18
|
Sound power level
|
Cooling
|
dBA
|
51
|
60
|
60
|
|
Heating
|
dBA
|
51
|
|
59
|
Dimensions
|
Unit
|
Width
|
mm
|
1,050
|
1,050
|
1,050
|
|
|
Depth
|
mm
|
200
|
200
|
200
|
|
|
Height
|
mm
|
490
|
490
|
490
|
Casing
|
Colour
|
|
Almond white
|
Almond white
|
Almond white
|
Weight
|
Unit
|
kg
|
16
|
17
|
17
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
|
Name
|
|
VM
|
VM
|
V1
|
|
Frequency
|
Hz
|
50/60
|
50/60
|
50
|
|
Voltage
|
V
|
220-240/220-230
|
220-240/220-230
|
230
|
Notes
|
(1) - 220V
|
(1) - 220V
|
(1) - SL: The silent fan level of the air flow rate setting
|
|
(2) - 230V
|
(2) - 230V
|
(2) - For cooling/heating capacity, maximum interunit piping length and maximum installation height difference, please refer to the specifications of the outdoor unit to be connected.
|
|
(3) - 240V
|
(3) - 240V
|
(3) - Contains fluorinated greenhouse gases
|
|
(4) - Sound values are measured in an anechoic room.
|
(4) - Sound values are measured in an anechoic room.
|
(4) - Electric characteristics are only for fan coil unit.
|
|
(5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
|
(5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
|
|
(6) - The sound power level is an absolute value indicating the power which a sound source generates.
|
(6) - The sound power level is an absolute value indicating the power which a sound source generates.
|
Standard Accessories
|
Extension auxiliary pipe
|
|
2
|
2
|
|
Installation manual
|
|
|
1
|
|
Operation manual
|
|
|
1
|
|
Wireless remote control
|
|
|
1
|
|
Heat insulating tape
|
|
|
2
|