| FTXG25JV1BS / RXG25K2V1B | FTXG35JV1BS / RXG35K2V1B | FTXG50JV1BS / RXG50K2V1B | ||||
|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.7 | |||
| Max. | kW | 5.3 | ||||
| Nom. | kW | 2.50 (3) | 3.50 (3) | 5.0 (3) | ||
| Piping connections | Liquid | OD | mm | 6.35 | ||
| Gas | OD | mm | 12.7 | |||
| Drain | OD | mm | 18.0 | |||
| Nominal efficiency | EER | 4.46 | 3.93 | 3.21 | ||
| Annual energy consumption | kWh | 280 | 445 | 780 | ||
| COP | 4.36 | 4.04 | 3.63 | |||
| Energy labeling Directive | Cooling | A | A | A | ||
| Heating | A | A | A | |||
| Heating capacity | Nom. | kW | 3.40 (4) | 4.00 (4) | 5.8 (4) | |
| Min. | kW | 1.7 | ||||
| Max. | kW | 6.5 | ||||
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | ||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB | ||||
| (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (5) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | ||||
| (6) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB | ||||||
| (7) - 220V | ||||||
| (8) - 230V | ||||||
| (9) - 240V | ||||||
| (10) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | ||||||
| (11) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||||