| FTXG25JV1BS / RXLG25K2V1B | FTXG35JV1BS / RXLG35K2V1B | ||||
|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.4 | |
| Max. | kW | 3.0 | 3.8 | ||
| Nom. | kW | 2.5 (3) | 3.5 (3) | ||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 |
| Gas | OD | mm | 9.5 | 9.5 | |
| Nominal efficiency | EER | 4.46 | 3.93 | ||
| Annual energy consumption | kWh | 280 | 445 | ||
| COP | 4.36 | 4.04 | |||
| Energy labeling Directive | Cooling | A | A | ||
| Heating | A | A | |||
| Heating capacity | Nom. | kW | 3.4 (4) | 4.5 (4) | |
| Min. | kW | 1.3 | 1.4 | ||
| Max. | kW | 4.5 | 5.0 | ||
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | ||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | ||||