| FTXG25JV1BA / RXG25K2V1B | FTXG25JV1BA / RXG25K3V1B | FTXG35JV1BA / RXG35K2V1B | FTXG35JV1BA / RXG35K3V1B | FTXG50JV1BA / RXG50K2V1B | FTXG50JV1BA / RXG50K3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | |
| Max. | kW | 3.0 | 3.0 | 3.8 | 3.8 | 5.3 | 5.3 | ||
| Nom. | kW | 2.5 (3) | 2.5 (2) | 3.5 (3) | 3.5 (2) | 5.0 (3) | 5.0 (2) | ||
| Space cooling | SEER | 6.53 | 6.51 | 5.45 | |||||
| Annual energy consumption | kWh/a | 134 | 188 | 321 | |||||
| Capacity | Pdesign | kW | 2.50 | 3.50 | 5.00 | ||||
| Energy efficiency class | A++ | A++ | A | ||||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.80 | 3.30 | 4.60 | |||
| SCOP/A | 4.34 | 4.23 | 3.87 | ||||||
| Energy efficiency class | A+ | A+ | A | ||||||
| Annual energy consumption | kWh/a | 903 | 1,091 | 1,660 | |||||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 |
| Gas | OD | mm | 9.52 | 9.52 | 9.52 | 9.52 | 12.7 | 12.7 | |
| Drain | OD | mm | 16 or 18 | 16 or 18 | 16 or 18 | 16 or 18 | 18.0 | 18.0 | |
| Nominal efficiency | EER | 4.46 | 4.46 (1) | 3.93 | 3.93 (1) | 3.21 | 3.21 (1) | ||
| Annual energy consumption | kWh | 280 | 280 | 445 | 445 | 780 | 780 | ||
| COP | 4.36 | 4.36 (1) | 4.04 | 4.04 (1) | 3.63 | 3.63 (1) | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | |||
| Heating capacity | Nom. | kW | 3.4 (4) | 3.4 (3) | 4.0 (4) | 4.0 (3) | 5.8 (4) | 5.8 (3) | |
| Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | ||
| Max. | kW | 4.5 | 4.5 | 5.0 | 5.0 | 6.5 | 6.5 | ||
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | ||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | ||||
| (5) - SL: The silent fan level of the air flow rate setting | (5) - SL: The silent fan level of the air flow rate setting | (5) - SL: The silent fan level of the air flow rate setting | |||||||
| (6) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | (6) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | (6) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected. | |||||||
| (7) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | (7) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | (7) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | |||||||
| (8) - 220V | (8) - 220V | (8) - 220V | |||||||
| (9) - 230V | (9) - 230V | (9) - 230V | |||||||
| (10) - 240V | (10) - 240V | (10) - 240V | |||||||
| (11) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (11) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (11) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | |||||||