Specifications Table for FTXG-JW / RXG-K

FTXG25JV1BW / RXG25K2V1B FTXG25JV1BW / RXG25K3V1B FTXG35JV1BW / RXG35K2V1B FTXG35JV1BW / RXG35K3V1B FTXG50JV1BW / RXG50K2V1B FTXG50JV1BW / RXG50K3V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Max. kW 3.0 3.0 3.8 3.8 5.3 5.3
  Nom. kW 2.5 (3) 2.5 (2) 3.5 (3) 3.5 (2) 5.0 (3) 5.0 (2)
Space cooling SEER     6.53   6.51   5.45
  Annual energy consumption kWh/a   134   188   321
  Capacity Pdesign kW   2.50   3.50   5.00
  Energy efficiency class     A++   A++   A
Space heating (Average climate) Capacity Pdesign kW   2.80   3.30   4.60
  SCOP/A     4.34   4.23   3.87
  Energy efficiency class     A+   A+   A
  Annual energy consumption kWh/a   903   1,091   1,660
Piping connections Liquid OD mm 6.35 6.35 6.35 6.35 6.35 6.35
  Gas OD mm 9.5 9.52 9.5 9.52 12.7 12.7
  Drain OD mm 16 or 18 16 or 18 16 or 18 16 or 18 18.0 18.0
Nominal efficiency EER   4.46 4.46 (1) 3.93 3.93 (1) 3.21 3.21 (1)
  Annual energy consumption kWh 280 280 445 445 780 780
  COP   4.36 4.36 (1) 4.04 4.04 (1) 3.63 3.63 (1)
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Heating capacity Nom. kW 3.4 (4) 3.4 (3) 4.0 (4) 4.0 (3) 5.8 (4) 5.8 (3)
  Min. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Max. kW 4.5 4.5 5.0 5.0 6.5 6.5
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (4) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
  (5) - SL: The silent fan level of the air flow rate setting   (5) - SL: The silent fan level of the air flow rate setting   (5) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  (6) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.   (6) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.   (6) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
  (7) - 220V   (7) - 220V   (7) - 220V
  (8) - 230V   (8) - 230V   (8) - 230V
  (9) - 240V   (9) - 240V   (9) - 240V
  (10) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (10) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (10) - When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.