Specifications Table for FTXM-N / 3MXM-N

FTXM20N2V1B / FTXM20N2V1B / 3MXM40N2V1B FTXM25N2V1B / FTXM25N2V1B / 3MXM52N2V1B FTXM25N2V1B / FTXM42N2V1B / 3MXM68N2V1B FTXM35N2V1B / FTXM35N2V1B / 3MXM68N2V1B
Cooling capacity Nom. kW 4.00 5.0 6.7 6.8
Space cooling SEER   8.52 8.59 7.99 8.02
  Annual energy consumption kWh/a 165 204 294 297
  Capacity Pdesign kW 4.00 5.00 6.70 6.80
  Energy efficiency class   A+++ A+++ A++ A++
Space heating (Average climate) Capacity Pdesign kW 4.80 4.80 4.30 4.80
  SCOP/A   4.24 4.38 3.86 4.00
  Energy efficiency class   A+ A+ A A+
  Pdh Heating capacity at -10° kW 3.60
  Annual energy consumption kWh/a 1,582 1,533 1,559 1,680
Nominal efficiency Annual energy consumption kWh 420 515 751 723
  EER   4.76 4.85 4.46 4.70
  COP   4.73 4.45 3.95 3.81
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Heating capacity Nom. kW 4.60 6.80 8.30 8.60
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data