Specifications Table for FTXS-J / RXL-J

FTXS20J2V1B / RXL20J2V1B FTXS25J2V1B / RXL25J2V1B FTXS35J2V1B / RXL35J2V1B FTXS35J2V1B / RXL35J3V1B FTXS42J2V1B / RXL42J3V1B FTXS50J2V1B / RXL50J2V1B FTXS50J2V1B / RXL50J3V1B
Cooling capacity Min. kW 1.3 1.3 1.4 1.4 1.7 1.7 1.7
  Nom. kW 2.0 (3) 2.5 (3) 3.5 (3) 3.5 (2) 4.2 (2) 5.0 (2) 5.0 (2)
  Max. kW 2.8 3.2 4.0 4.0 5.0 5.3 5.3
Heating capacity Min. kW 1.3 1.3 1.4 1.4 1.7 1.7 1.7
  Nom. kW 2.7 (4) 3.3 (4) 4.0 (4) 4.0 (3) 5.4 (3) 5.8 (3) 5.8 (3)
  Max. kW 4.3 4.7 5.2 5.2 6.0 6.5 6.5
Nominal efficiency Annual energy consumption kWh 225 268 430 430 605 730 730
  COP   4.43 4.65 4.21 4.21 (1) 3.72 (1) 3.79 (1) 3.79 (1)
  EER   4.44 4.67 4.07 4.07 (1) 3.47 (1) 3.42 (1) 3.42 (1)
  Energy labeling Directive Cooling   A A A A A A A
    Heating   A A A A A A A
Space cooling Annual energy consumption kWh/a       190 269   330
  Energy efficiency class         A++ A   A
  Capacity Pdesign kW       3.50 4.20   5.00
  SEER         6.43 5.47   5.30
Space heating (Average climate) Annual energy consumption kWh/a       1,188 1,453   1,634
  Capacity Pdesign kW       3.60 3.90   4.60
  Energy efficiency class         A+ A   A
  SCOP/A         4.24 3.75   3.94
Piping connections Drain OD mm       18.0 18.0 18.0 18.0
  Gas OD mm 9.5 9.5 9.5 9.5 9.5 12.7 12.7
  Liquid OD mm 6.35 6.35 6.35 6.35 6.35 6.35 6.35
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (4) - 220V (4) - 220V (4) - 220V (4) - 220V
  (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - 230V (5) - 230V (5) - 230V (5) - 230V
        (6) - 240V (6) - 240V (6) - 240V (6) - 240V
        (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load