| FTXS20J2V1B / RXL20J2V1B | FTXS25J2V1B / RXL25J2V1B | FTXS35J2V1B / RXL35J2V1B | FTXS35J2V1B / RXL35J3V1B | FTXS42J2V1B / RXL42J3V1B | FTXS50J2V1B / RXL50J2V1B | FTXS50J2V1B / RXL50J3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | 1.7 | |
| Nom. | kW | 2.0 (3) | 2.5 (3) | 3.5 (3) | 3.5 (2) | 4.2 (2) | 5.0 (2) | 5.0 (2) | ||
| Max. | kW | 2.8 | 3.2 | 4.0 | 4.0 | 5.0 | 5.3 | 5.3 | ||
| Heating capacity | Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | 1.7 | |
| Nom. | kW | 2.7 (4) | 3.3 (4) | 4.0 (4) | 4.0 (3) | 5.4 (3) | 5.8 (3) | 5.8 (3) | ||
| Max. | kW | 4.3 | 4.7 | 5.2 | 5.2 | 6.0 | 6.5 | 6.5 | ||
| Nominal efficiency | Annual energy consumption | kWh | 225 | 268 | 430 | 430 | 605 | 730 | 730 | |
| COP | 4.43 | 4.65 | 4.21 | 4.21 (1) | 3.72 (1) | 3.79 (1) | 3.79 (1) | |||
| EER | 4.44 | 4.67 | 4.07 | 4.07 (1) | 3.47 (1) | 3.42 (1) | 3.42 (1) | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | A | A | ||
| Heating | A | A | A | A | A | A | A | |||
| Space cooling | Annual energy consumption | kWh/a | 190 | 269 | 330 | |||||
| Energy efficiency class | A++ | A | A | |||||||
| Capacity | Pdesign | kW | 3.50 | 4.20 | 5.00 | |||||
| SEER | 6.43 | 5.47 | 5.30 | |||||||
| Space heating (Average climate) | Annual energy consumption | kWh/a | 1,188 | 1,453 | 1,634 | |||||
| Capacity | Pdesign | kW | 3.60 | 3.90 | 4.60 | |||||
| Energy efficiency class | A+ | A | A | |||||||
| SCOP/A | 4.24 | 3.75 | 3.94 | |||||||
| Piping connections | Drain | OD | mm | 18.0 | 18.0 | 18.0 | 18.0 | |||
| Gas | OD | mm | 9.5 | 9.5 | 9.5 | 9.5 | 9.5 | 12.7 | 12.7 | |
| Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | |
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | ||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (4) - 220V | (4) - 220V | (4) - 220V | (4) - 220V | ||||
| (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (5) - 230V | (5) - 230V | (5) - 230V | (5) - 230V | ||||
| (6) - 240V | (6) - 240V | (6) - 240V | (6) - 240V | |||||||
| (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | |||||||