Specifications Table for FVXM-A / RXTP-R

FVXM25A2V1B / RXTP25R2V1B FVXM25A3V1B / RXTP25R2V1B FVXM35A2V1B / RXTP35R2V1B FVXM35A3V1B / RXTP35R2V1B
Cooling capacity Min. kW 1.40 1.40 1.40 1.40
  Max. kW 4.20 4.20 4.30 4.30
  Nom. kW 2.50 2.50 3.50 3.50
Space cooling SEER   6.50 6.50 6.10 6.10
  Annual energy consumption kWh/a 135 135 201 201
  Capacity Pdesign kW 2.50 2.50 3.50 3.50
  Energy efficiency class   A++ A++ A++ A++
Space heating (Average climate) Capacity Pdesign kW 2.50 2.50 3.00 3.00
  SCOP/A   4.70 4.70 4.60 4.62
  Energy efficiency class   A++ A++ A++ A++
  Pdh Heating capacity at -10° kW 2.50 2.50 3.00 3.00
  Annual energy consumption kWh/a 744 744 913 909
Nominal efficiency Annual energy consumption kWh 328 328 510 510
  EER   3.81 3.81 3.43 3.43
  COP   3.86 3.86 3.54 3.54
  Energy labeling Directive Cooling   A A A A
    Heating   A A B B
Heating capacity Nom. kW 3.20 3.20 4.00 4.00
  Min. kW 1.20 1.20 1.20 1.20
  Max. kW 5.70 5.70 6.20 6.20
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data
  (4) - See separate drawing for operation range (4) - See separate drawing for operation range (4) - See separate drawing for operation range (4) - See separate drawing for operation range