Specifications Table for FVXS-F / RXL-J

FVXS25FV1B / RXL25J2V1B FVXS25FV1B / RXL25J3V1B (Preliminary) FVXS35FV1B / RXL35J2V1B FVXS35FV1B / RXL35J3V1B FVXS50FV1B / RXL50J2V1B FVXS50FV1B / RXL50J3V1B
Cooling capacity Min. kW 1.3   1.4 1.4 1.4 1.4
  Max. kW 3.0   3.8 3.8 5.6 5.6
  Nom. kW 2.5 (3)   3.5 (3) 3.5 (2) 5.0 (2) 5.0 (2)
Space cooling SEER         4.93   5.53
  Annual energy consumption kWh/a       248   317
  Capacity Pdesign kW       3.50   5.00
  Energy efficiency class         B   A
Space heating (Average climate) Capacity Pdesign kW       2.90   4.80
  SCOP/A         3.77   3.59
  Energy efficiency class         A   A
  Annual energy consumption kWh/a       1,077   1,874
Piping connections Liquid OD mm 6.35   6.35 6.35 6.35 6.35
  Gas OD mm 9.5   9.5 9.5 12.7 12.7
  Drain OD mm       20.0 20.0 20.0
Nominal efficiency EER   4.39   4.30 3.43 (1) 3.23 (1) 3.23 (1)
  Annual energy consumption kWh 285   407 510 775 775
  COP   3.43   3.69 3.69 (1) 3.63 (1) 3.63 (1)
  Energy labeling Directive Cooling   A   A A A A
    Heating   B   A A A A
Heating capacity Nom. kW 3.4 (4)   4.5 (4) 4.5 (3) 5.8 (3) 5.8 (3)
  Min. kW 1.3   1.4 1.4 1.4 1.4
  Max. kW 4.5   5.0 5.0 8.1 8.1
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal)   (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal)   (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) (4) - 220V (4) - 220V (4) - 220V
  (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (5) - 230V (5) - 230V (5) - 230V
        (6) - 240V (6) - 240V (6) - 240V
        (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load