| FVXS25FV1B / RXL25J2V1B | FVXS25FV1B / RXL25J3V1B (Preliminary) | FVXS35FV1B / RXL35J2V1B | FVXS35FV1B / RXL35J3V1B | FVXS50FV1B / RXL50J2V1B | FVXS50FV1B / RXL50J3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.3 | 1.4 | 1.4 | 1.4 | 1.4 | ||
| Max. | kW | 3.0 | 3.8 | 3.8 | 5.6 | 5.6 | |||
| Nom. | kW | 2.5 (3) | 3.5 (3) | 3.5 (2) | 5.0 (2) | 5.0 (2) | |||
| Space cooling | SEER | 4.93 | 5.53 | ||||||
| Annual energy consumption | kWh/a | 248 | 317 | ||||||
| Capacity | Pdesign | kW | 3.50 | 5.00 | |||||
| Energy efficiency class | B | A | |||||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.90 | 4.80 | ||||
| SCOP/A | 3.77 | 3.59 | |||||||
| Energy efficiency class | A | A | |||||||
| Annual energy consumption | kWh/a | 1,077 | 1,874 | ||||||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | |
| Gas | OD | mm | 9.5 | 9.5 | 9.5 | 12.7 | 12.7 | ||
| Drain | OD | mm | 20.0 | 20.0 | 20.0 | ||||
| Nominal efficiency | EER | 4.39 | 4.30 | 3.43 (1) | 3.23 (1) | 3.23 (1) | |||
| Annual energy consumption | kWh | 285 | 407 | 510 | 775 | 775 | |||
| COP | 3.43 | 3.69 | 3.69 (1) | 3.63 (1) | 3.63 (1) | ||||
| Energy labeling Directive | Cooling | A | A | A | A | A | |||
| Heating | B | A | A | A | A | ||||
| Heating capacity | Nom. | kW | 3.4 (4) | 4.5 (4) | 4.5 (3) | 5.8 (3) | 5.8 (3) | ||
| Min. | kW | 1.3 | 1.4 | 1.4 | 1.4 | 1.4 | |||
| Max. | kW | 4.5 | 5.0 | 5.0 | 8.1 | 8.1 | |||
| Notes | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - Energy label: scale from A (most efficient) to G (less efficient) | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | (1) - EER/COP according to Eurovent 2012, for use outside EU only | |||
| (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | ||||
| (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (horizontal) | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | |||||
| (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal) | (4) - 220V | (4) - 220V | (4) - 220V | |||||
| (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (5) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (5) - 230V | (5) - 230V | (5) - 230V | |||||
| (6) - 240V | (6) - 240V | (6) - 240V | |||||||
| (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load | |||||||