| 2MXS40G2V1B | 2MXS50G2V1B | |||||
|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 48 | 50 | |
| Cooling | Nom. | dBA | 47 | 48 | ||
| Standard Accessories | Installation manual | 1 | 1 | |||
| Screw bag | 1 | 1 | ||||
| Drain plug | 1 | 1 | ||||
| Air direction adjustment plate | Air direction adjustment plate | Air direction adjustment plate | ||||
| Refrigerant | Charge | TCO2Eq | 2.5 | 3.3 | ||
| GWP | 2,087.5 | 2,087.5 | ||||
| Charge | kg | 1.20 | 1.60 | |||
| Type | R-410A | R-410A | ||||
| Piping connections | Level difference | IU - IU | Max. | m | 7.5 | 7.5 |
| IU - OU | Max. | m | 15 | 15 | ||
| Additional refrigerant charge | kg/m | 0.02 (for piping length exceeding 20m) | 0.02 (for piping length exceeding 20m) | |||
| Total piping length | System | Actual | m | 30 | 30 | |
| Sound power level | Cooling | dBA | 62 | 63 | ||
| Dimensions | Unit | Width | mm | 765 | 765 | |
| Depth | mm | 285 | 285 | |||
| Height | mm | 550 | 550 | |||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | |||
| Weight | Unit | kg | 38 | 42 | ||
| Power supply | Phase | 1~ | 1~ | |||
| Frequency | Hz | 50 | 50 | |||
| Voltage | V | 220-240 | 220-240 | |||
| Notes | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m | ||||
| (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | |||||
| (3) - Contains fluorinated greenhouse gases | (3) - Contains fluorinated greenhouse gases | |||||
| Standard Accessories | Reducer assembly | 1 | ||||