| REQ71B8W1B | REQ100B8W1B | REQ125B8W1B | |||||
|---|---|---|---|---|---|---|---|
| Sound pressure level | Cooling | Nom. | dBA | 53.0 | 57.0 | 57.0 | |
| Standard Accessories | Declaration of conformity | 1 | 1 | 1 | |||
| Installation manual | 1 | 1 | 1 | ||||
| Refrigerant | Charge | TCO2Eq | 5.2 | 7.5 | 7.5 | ||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | ||||
| Charge | kg | 2.5 | 3.6 | 3.6 | |||
| Type | R-410A | R-410A | R-410A | ||||
| Piping connections | Piping length | OU - IU | Max. | m | 50 | 50 | 50 |
| System | Chargeless | m | 7.5 | 7.5 | 7.5 | ||
| Equivalent | m | 70 | 70 | 70 | |||
| Level difference | IU - IU | Max. | m | 0.5 | 0.5 | 0.5 | |
| IU - OU | Max. | m | 30.0 | 30.0 | 30.0 | ||
| Sound power level | Cooling | dBA | 65.0 | 70.0 | 70.0 | ||
| Dimensions | Unit | Width | mm | 900 | 900 | 900 | |
| Depth | mm | 320 | 320 | 320 | |||
| Height | mm | 770 | 1,170 | 1,170 | |||
| Compressor | Type | Hermetically sealed scroll compressor | Hermetically sealed scroll compressor | Hermetically sealed scroll compressor | |||
| Weight | Unit | kg | 83 | 100 | 108 | ||
| Power supply | Phase | 3N~ | 3N~ | 3N~ | |||
| Frequency | Hz | 50 | 50 | 50 | |||
| Voltage | V | 400 | 400 | 400 | |||
| Notes | (1) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | (1) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | (1) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | ||||
| (2) - The sound power level is an absolute value indicating the power which a sound source generates. | (2) - The sound power level is an absolute value indicating the power which a sound source generates. | (2) - The sound power level is an absolute value indicating the power which a sound source generates. | |||||
| (3) - Sound values are measured in a semi-anechoic room. | (3) - Sound values are measured in a semi-anechoic room. | (3) - Sound values are measured in a semi-anechoic room. | |||||
| (4) - In case of drain piping for the outdoor unit, a drain piping kit (option) is needed. | (4) - In case of drain piping for the outdoor unit, a drain piping kit (option) is needed. | (4) - In case of drain piping for the outdoor unit, a drain piping kit (option) is needed. | |||||
| (5) - 230V | (5) - 230V | (5) - 230V | |||||
| (6) - Contains fluorinated greenhouse gases | (6) - Contains fluorinated greenhouse gases | (6) - Contains fluorinated greenhouse gases | |||||