RQ71B2V3B |
RQ100B8V3B |
Sound pressure level
|
Cooling
|
Nom.
|
dBA
|
50.0
|
53.0
|
Standard Accessories
|
Declaration of conformity
|
1
|
1
|
|
Installation manual
|
1
|
1
|
Refrigerant
|
Charge
|
TCO2Eq
|
5.6
|
7.7
|
|
GWP
|
|
2,087.5
|
2,087.5
|
|
Charge
|
kg
|
2.70
|
3.70
|
|
Type
|
|
R-410A
|
R-410A
|
Operation range
|
Cooling
|
Ambient
|
Max.
|
°CDB
|
46.0
|
46.0
|
|
|
|
Min.
|
°CDB
|
-5.0
|
-5.0
|
|
Heating
|
Ambient
|
Max.
|
°CWB
|
15.0
|
15.0
|
|
|
|
Min.
|
°CWB
|
-10.0
|
-10.0
|
Piping connections
|
Piping length
|
OU - IU
|
Max.
|
m
|
70
|
70
|
|
|
System
|
Chargeless
|
m
|
30
|
30
|
|
|
|
Equivalent
|
m
|
90
|
90
|
|
Level difference
|
IU - IU
|
Max.
|
m
|
0.5
|
0.5
|
|
|
IU - OU
|
Max.
|
m
|
30.0
|
30.0
|
Sound power level
|
Cooling
|
dBA
|
63.0
|
66.0
|
Dimensions
|
Unit
|
Width
|
mm
|
900
|
900
|
|
|
Depth
|
mm
|
320
|
320
|
|
|
Height
|
mm
|
770
|
1,170
|
Compressor
|
Type
|
|
Hermetically sealed scroll compressor
|
Hermetically sealed scroll compressor
|
Weight
|
Unit
|
kg
|
84
|
103
|
Power supply
|
Phase
|
|
1~
|
1~
|
|
Frequency
|
Hz
|
50
|
50
|
|
Voltage
|
V
|
230
|
230
|
Notes
|
(1) - Contains fluorinated greenhouse gases
|
(1) - Contains fluorinated greenhouse gases
|