| RXG25K3V1B | RXG25K2V1B | RXG35K3V1B | RXG35K2V1B | RXG50K3V1B | RXG50K2V1B | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | High | dBA | 47 | 48 | 48 | ||||
| Cooling | High | dBA | 46 | 48 | 48 | |||||
| Refrigerant | Charge | TCO2Eq | 2.2 | 2.2 | 3.3 | |||||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | |||||||
| Charge | kg | 1.05 | 1.05 | 1.6 | ||||||
| Type | R-410A | R-410A | R-410A | |||||||
| Fan motor | Speed | Cooling | Super low | rpm | 780 | 780 | 670 | |||
| Heating | Super low | rpm | 740 | 740 | 670 | |||||
| Piping connections | Level difference | IU - OU | Max. | m | 15 | 15 | 20 | |||
| Additional refrigerant charge | kg/m | 0.02 (for piping length exceeding 10m) | 0.02 (for piping length exceeding 10m) | 0.02 (for piping length exceeding 10m) | ||||||
| Dimensions | Unit | Width | mm | 765 | 765 | 825 | ||||
| Depth | mm | 285 | 285 | 300 | ||||||
| Height | mm | 550 | 550 | 735 | ||||||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | ||||||
| Weight | Unit | kg | 34 | 34 | 48 | |||||
| Fan | Air flow rate | Heating | Super low | cfm | 904 | 904 | 1,522 | |||
| Cooling | Super low | cfm | 1,063 | 1,063 | 1,727 | |||||
| Power supply | Phase | 1~ | 1~ | 1~ | ||||||
| Frequency | Hz | 50 | 50 | 50 | ||||||
| Voltage | V | 220-240 | 220-240 | 220-240 | ||||||
| Notes | (1) - 220V | (1) - 220V | (1) - 220V | (1) - 220V | (1) - 220V | (1) - 220V | ||||
| (2) - 230V | (2) - 230V | (2) - 230V | (2) - 230V | (2) - 230V | (2) - 230V | |||||
| (3) - 240V | (3) - 240V | (3) - 240V | (3) - 240V | (3) - 240V | (3) - 240V | |||||
| (4) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | (4) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | (4) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | (4) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | (4) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | (4) - Operation range in combination with Nexura, FVXG-K: min. 10°CDB ~ max. 46°CDB | |||||
| (5) - Contains fluorinated greenhouse gases | (5) - Contains fluorinated greenhouse gases | (5) - Contains fluorinated greenhouse gases | ||||||||
| Fan | Air flow rate | Cooling | Super low | m³/min | 30.1 | 30.1 | 48.9 | |||
| Heating | Super low | m³/min | 25.6 | 25.6 | 43.1 | |||||
| Super low | cfm | 1063 | 1063 | 1727 | ||||||
| Heating | Super low | cfm | 904 | 904 | 1522 | |||||
| Dimensions | Unit | Height | mm | 550 | 550 | 735 | ||||
| Width | mm | 765 | 765 | 825 | ||||||
| Depth | mm | 285 | 285 | 300 | ||||||
| Weight | Unit | kg | 34 | 34 | 48 | |||||
| Fan motor | Speed | Cooling | Super low | rpm | 780 | 780 | 670 | |||
| Heating | Super low | rpm | 740 | 740 | 670 | |||||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | ||||||
| Operation range | Cooling | Ambient | Min. | °CDB | -10 | -10 | -10 | |||
| Max. | °CDB | 46 | 46 | 46 | ||||||
| Heating | Ambient | Min. | °CWB | -15 | -15 | -15 | ||||
| Max. | °CWB | 20 | 20 | 20 | ||||||
| Sound pressure level | Cooling | High | dBA | 46 | 48 | 48 | ||||
| Heating | High | dBA | 47 | 48 | 48 | |||||
| Refrigerant | Type | R-410A | R-410A | R-410A | ||||||
| Charge | kg | 1.05 | 1.05 | 1.6 | ||||||
| Charge | tCO2Eq | 2.2 | 2.2 | 3.3 | ||||||
| GWP | 2087.5 | 2087.5 | 2087.5 | |||||||
| Piping connections | Piping length | OU - IU | Max. | m | 20 | 20 | 30 | |||
| Additional refrigerant charge | kg/m | 0.02 (for piping length exceeding 10m) | 0.02 (for piping length exceeding 10m) | 0.02 (for piping length exceeding 10m) | ||||||
| Level difference | IU - OU | Max. | m | 15 | 15 | 20 | ||||
| Power supply | Phase | 1~ | 1~ | 1~ | ||||||
| Frequency | Hz | 50 | 50 | 50 | ||||||
| Voltage | V | 220-240 | 220-240 | 220-240 | ||||||