RZQ71D7V1B |
RZQ100D7V1B |
RZQ125D7V1B |
RZQ140D7V1B |
Sound pressure level
|
Heating
|
Nom.
|
dBA
|
50
|
52
|
53
|
53
|
|
Cooling
|
Nom.
|
dBA
|
48
|
50
|
51
|
51
|
|
Night quiet mode
|
Level 1
|
dBA
|
43
|
45
|
45
|
46
|
Standard Accessories
|
Tie-wraps
|
2
|
2
|
2
|
2
|
|
Installation manual
|
1
|
1
|
1
|
1
|
Refrigerant
|
Charge
|
TCO2Eq
|
5.7
|
8.2
|
8.2
|
8.2
|
|
GWP
|
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
|
Charge
|
kg
|
2.75
|
3.95
|
3.95
|
3.95
|
|
Type
|
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
Piping connections
|
Liquid
|
OD
|
mm
|
9.52
|
9.52
|
9.52
|
9.52
|
|
Piping length
|
OU - IU
|
Max.
|
m
|
50
|
75
|
75
|
75
|
|
|
System
|
Chargeless
|
m
|
30
|
30
|
30
|
30
|
|
|
|
Equivalent
|
m
|
70
|
95
|
95
|
95
|
|
Gas
|
OD
|
mm
|
15.9
|
15.9
|
15.9
|
15.9
|
|
Level difference
|
IU - IU
|
Max.
|
m
|
0.5
|
0.5
|
0.5
|
0.5
|
|
|
IU - OU
|
Max.
|
m
|
30.0
|
30.0
|
30.0
|
30.0
|
|
Additional refrigerant charge
|
kg/m
|
See installation manual 4PW48323-1
|
See installation manual 4PW48323-1
|
See installation manual 4PW48323-1
|
See installation manual 4PW48323-1
|
Sound power level
|
Cooling
|
dBA
|
64
|
65
|
67
|
68
|
Dimensions
|
Unit
|
Width
|
mm
|
900
|
900
|
900
|
900
|
|
|
Depth
|
mm
|
320
|
320
|
320
|
320
|
|
|
Height
|
mm
|
770
|
1,345
|
1,345
|
1,345
|
Compressor
|
Type
|
|
Hermetically sealed swing compressor
|
Hermetically sealed scroll compressor
|
Hermetically sealed scroll compressor
|
Hermetically sealed scroll compressor
|
Weight
|
Unit
|
kg
|
67
|
109
|
109
|
109
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
|
Frequency
|
Hz
|
50
|
50
|
50
|
50
|
|
Voltage
|
V
|
220-240
|
220-240
|
220-240
|
220-240
|
Notes
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
(1) - See separate drawing for electrical data
|
|
(2) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
|
(2) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
|
(2) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
|
(2) - Minimum Ssc value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase
|
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
|
(4) - 230V
|
(4) - 230V
|
(4) - 230V
|
(4) - 230V
|
|
(5) - Contains fluorinated greenhouse gases
|
(5) - Contains fluorinated greenhouse gases
|
(5) - Power supply to the FDQ indoor unit is separate
|
(5) - Contains fluorinated greenhouse gases
|
|
|
|
(6) - Contains fluorinated greenhouse gases
|