| RZQG71L7V1B | RZQG71L7Y1B9 | RZQG100L7Y1B | RZQG100L7V1B | RZQG125L7V1B | RZQG125L7Y1B | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 50 | 50 | 52 | 53 | 53 | ||
| Cooling | Nom. | dBA | 48 | 48 | 50 | 51 | 51 | |||
| Night quiet mode | Level 1 | dBA | 43 | 43 | 45 | 45 | 45 | |||
| Standard Accessories | Tie-wraps | 2 | 2 | 2 | 2 | 2 | 2 | |||
| Installation manual | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| Refrigerant | Charge | TCO2Eq | 6.1 | 6.1 | 8.4 | 8.4 | 8.4 | |||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | |||||
| Charge | kg | 2.9 | 2.9 | 4.0 | 4.0 | 4.0 | ||||
| Type | R-410A | R-410A | R-410A | R-410A | R-410A | |||||
| Piping connections | Liquid | OD | mm | 9.52 | 9.52 | 9.52 | 9.52 | 9.52 | ||
| Piping length | OU - IU | Max. | m | 50 | 50 | 75 | 75 | 75 | ||
| System | Chargeless | m | 30 | 30 | 30 | 30 | 30 | |||
| Equivalent | m | 70 | 70 | 90 | 90 | 90 | ||||
| Gas | OD | mm | 15.9 | 15.9 | 15.9 | 15.9 | 15.9 | |||
| Level difference | IU - IU | Max. | m | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | ||
| IU - OU | Max. | m | 30.0 | 30.0 | 30.0 | 30.0 | 30.0 | |||
| Additional refrigerant charge | kg/m | See installation manual 4P302555-1 | See installation manual 4P302555-1 | See installation manual 4P302555-1 | See installation manual 4P302555-1 | See installation manual 4P302555-1 | ||||
| Sound power level | Cooling | dBA | 64 | 64 | 66 | 67 | 67 | |||
| Dimensions | Unit | Width | mm | 940 | 940 | 940 | 940 | 940 | ||
| Depth | mm | 320 | 320 | 320 | 320 | 320 | ||||
| Height | mm | 990 | 990 | 1,430 | 1,430 | 1,430 | ||||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | ||||
| Weight | Unit | kg | 78 | 80 | 101 | 102 | 101 | |||
| Current - 50Hz | Maximum fuse amps (MFA) | A | 20 | 16 | 20 | 32 | 20 | |||
| Power supply | Phase | 1~ | 3N~ | 3N~ | 1~ | 3N~ | ||||
| Frequency | Hz | 50 | 50 | 50 | 50 | 50 | ||||
| Voltage | V | 220-240 | 380-415 | 380-415 | 220-240 | 380-415 | ||||
| Notes | (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (1) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||||
| (2) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (2) - 3 with re-charging | (2) - 3 with re-charging | (2) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase | (2) - 3 with re-charging | ||||||
| (3) - Short-circuit power | (3) - See separate drawing for electrical data | (3) - See separate drawing for electrical data | (3) - Short-circuit power | (3) - See separate drawing for electrical data | ||||||
| (4) - See separate drawing for electrical data | (4) - Contains fluorinated greenhouse gases | (4) - Contains fluorinated greenhouse gases | (4) - See separate drawing for electrical data | (4) - Contains fluorinated greenhouse gases | ||||||
| (5) - 3 with re-charging | (5) - 3 with re-charging | |||||||||
| (6) - Contains fluorinated greenhouse gases | (6) - Contains fluorinated greenhouse gases | |||||||||
| Sound power level | Cooling | dBA | 66 | |||||||
| Dimensions | Unit | Height | mm | 1430 | ||||||
| Width | mm | 940 | ||||||||
| Depth | mm | 320 | ||||||||
| Weight | Unit | kg | 102 | |||||||
| Operation range | Cooling | Ambient | Min. | °CDB | -15.0 | |||||
| Max. | °CDB | 50.0 | ||||||||
| Heating | Ambient | Min. | °CWB | -20.0 | ||||||
| Max. | °CWB | 15.5 | ||||||||
| Sound pressure level | Cooling | Nom. | dBA | 50 | ||||||
| Heating | Nom. | dBA | 52 | |||||||
| Night quiet mode | Level 1 | dBA | 45 | |||||||
| Refrigerant | Charge | kg | 4.0 | |||||||
| Charge | tCO2Eq | 8.4 | ||||||||
| GWP | 2087.5 | |||||||||
| Piping connections | Piping length | OU - IU | Max. | m | 75 | |||||
| Level difference | IU - OU | Max. | m | 30.0 | ||||||
| IU - IU | Max. | m | 0.5 | |||||||
| Power supply | Frequency | Hz | 50 | |||||||
| Notes | (5) - 3 with re-charging | |||||||||