| RZQG71L8Y1L | RZQG100L8Y1L | RZQG125L8Y1L | RZQG140L7Y1L | |||||
|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 50 | 52 | 53 | 53 | |
| Cooling | Nom. | dBA | 48 | 50 | 51 | 52 | ||
| Night quiet mode | Level 1 | dBA | 43 | 45 | 45 | 45 | ||
| Standard Accessories | Tie-wraps | 2 | 2 | 2 | 2 | |||
| Installation manual | 1 | 1 | 1 | 1 | ||||
| Refrigerant | Charge | TCO2Eq | 6.10 | 8.40 | 8.40 | 8.40 | ||
| GWP | 2,087.5 | 2,087.5 | 2,087.5 | 2,087.5 | ||||
| Charge | kg | 2.9 | 4.0 | 4.0 | 4.0 | |||
| Type | R-410A | R-410A | R-410A | R-410A | ||||
| Piping connections | Liquid | OD | mm | 9.52 | 9.52 | 9.52 | 9.52 | |
| Piping length | OU - IU | Max. | m | 50 | 75 | 75 | 75 | |
| System | Chargeless | m | 30 | 30 | 30 | 30 | ||
| Equivalent | m | 70 | 90 | 90 | 90 | |||
| Gas | OD | mm | 15.9 | 15.9 | 15.9 | 15.9 | ||
| Level difference | IU - IU | Max. | m | 0.5 | 0.5 | 0.5 | 0.5 | |
| IU - OU | Max. | m | 30.0 | 30.0 | 30.0 | 30.0 | ||
| Additional refrigerant charge | kg/m | See installation manual | See installation manual | See installation manual | See installation manual | |||
| Sound power level | Cooling | dBA | 64 | 66 | 67 | 69 | ||
| Dimensions | Unit | Width | mm | 940 | 940 | 940 | 940 | |
| Depth | mm | 320 | 320 | 320 | 320 | |||
| Height | mm | 990 | 1,430 | 1,430 | 1,430 | |||
| Compressor | Type | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | Hermetically sealed swing compressor | |||
| Weight | Unit | kg | 80 | 101 | 101 | 101 | ||
| Current - 50Hz | Maximum fuse amps (MFA) | A | 16 | 25 | 25 | 25 | ||
| Power supply | Phase | 3N~ | 3N~ | 3N~ | 3N~ | |||
| Frequency | Hz | 50 | 50 | 50 | 50 | |||
| Voltage | V | 380-415 | 380-415 | 380-415 | 380-415 | |||
| Notes | (1) - 3 with re-charging | (1) - 3 with re-charging | (1) - 3 with re-charging | (1) - 3 with re-charging | ||||
| (2) - See separate drawings for electrical data | (2) - See separate drawings for electrical data | (2) - See separate drawings for electrical data | (2) - See separate drawings for electrical data | |||||
| (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (3) - PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||||